Explore performance details, construction highlights, applications, and technical information in one clear overview.
HD6 is a Hanyoung NUX temperature controller for monitoring and regulating process temperature. The available configuration is built around the listed sensor inputs, control method and output arrangement, with model information of Description | Description. Control output (Relay): OPEN OUT : 250 V a.c. 5 A , CLOSE OUT : 250 V a.c. 5 A; Control output: M | Relay; Indicate accuracy: ±1 % +1 Digit; Power supply voltage: 100 - 240 V a.c. 50 - 60 Hz.
For panel and process selection, the important characteristics are the input sensor type, control response, power requirements and display or communication options. Setting method: Digital method by FND and button; Weight: 116 g; Ambient Temperature: 0 ~ 50 ℃; Ambient Humidity: 85 % R.H. max..
Key strengths of the HD6 come from the combination of its functional configuration and practical installation specifications. The following characteristics highlight the values that matter most when comparing the product with equipment requirements.
Input: TH-540N (103ET : -40.0 ~ 90.0 ℃, 2 m ~ 20 m); Control output (Relay): OPEN OUT : 250 V a.c. 5 A , CLOSE OUT : 250 V a.c. 5 A; Power supply voltage: 100 - 240 V a.c. 50 - 60 Hz; Power consumption: 2 VA max.; Control output: M | Relay.
The HD6 is specified by its sensor input, control output, electrical supply, sampling behaviour and accuracy. These values determine how the controller measures temperature and applies its selected control response. Power consumption: 2 VA max.; Power supply voltage: P4 | 100 - 240 V a.c.; Input: TH-540N (103ET : -40.0 ~ 90.0 ℃, 2 m ~ 20 m); Control output (Relay): OPEN OUT : 250 V a.c. 5 A , CLOSE OUT : 250 V a.c. 5 A.
Additional technical characteristics include Power supply voltage: 100 - 240 V a.c. 50 - 60 Hz; Control output: M | Relay; Indicate accuracy: ±1 % +1 Digit.
The physical design of HD6 should be considered together with the installation environment and the available mounting or display arrangement. Input: TH-540N (103ET : -40.0 ~ 90.0 ℃, 2 m ~ 20 m); Control output (Relay): OPEN OUT : 250 V a.c. 5 A , CLOSE OUT : 250 V a.c. 5 A; Power supply voltage: 100 - 240 V a.c. 50 - 60 Hz; Power consumption: 2 VA max..
Further construction and environmental details include Control output: M | Relay; Indicate accuracy: ±1 % +1 Digit; Power supply voltage: P4 | 100 - 240 V a.c..
Integration of HD6 requires the correct sensor input, control output, supply voltage and configuration settings for the application. Input: TH-540N (103ET : -40.0 ~ 90.0 ℃, 2 m ~ 20 m); Control output (Relay): OPEN OUT : 250 V a.c. 5 A , CLOSE OUT : 250 V a.c. 5 A; Power supply voltage: 100 - 240 V a.c. 50 - 60 Hz; Power consumption: 2 VA max..
Additional operating and interface details include Control output: M | Relay; Indicate accuracy: ±1 % +1 Digit; Power supply voltage: P4 | 100 - 240 V a.c.. These values provide a practical reference for wiring, setup and normal operation within the selected configuration.
Choose HD6 by confirming the exact model or configuration against the required operating conditions. The available model information is Description | Description. Model: Description | Description; Option: 0 | None sensor; Input: TH-540N (103ET : -40.0 ~ 90.0 ℃, 2 m ~ 20 m); Control output (Relay): OPEN OUT : 250 V a.c. 5 A , CLOSE OUT : 250 V a.c. 5 A.
Before installation, confirm Power supply voltage: 100 - 240 V a.c. 50 - 60 Hz; Power consumption: 2 VA max.; Control output: M | Relay. Matching the model, electrical ratings, signal requirements, physical arrangement and environmental limits helps keep the product within its specified operating conditions.
| Specification | Details |
|---|---|
| Power supply voltage | 100 - 240 V a.c. 50 - 60 Hz |
| Power consumption | 2 VA max. |
| Input | TH-540N (103ET : -40.0 ~ 90.0 ℃, 2 m ~ 20 m) |
| Indicate accuracy | ±1 % +1 Digit |
| Control output (Relay) | OPEN OUT : 250 V a.c. 5 A , CLOSE OUT : 250 V a.c. 5 A |
| Control operation | ON/OFF control (Control by temperature and time) |
| Setting method | Digital method by FND and button |
| Ambient Temperature | 0 ~ 50 ℃ |
| Ambient Humidity | 85 ï¼… R.H. max. |
| Weight | 116 g |
| Model | Description | Description |
| HD6- | - | Green house open / close motor control only |
| Control type | F | ON / OFF Control |
| Input | N | TH-540N(103ET) |
| Control output | M | Relay |
| Power supply voltage | P4 | 100 - 240 V a.c. |
| Option | 0 | None sensor |
| 2 | 2 m Include sensor |
| 3 | 3 m Include sensor |
| 5 | 5 m Include sensor |
| 10 | 10 m Include sensor |
| 15 | 15 m Include sensor |
| 20 | 20 m Include sensor |
| No | Type | Category | Title | File |
| 1 | Manual > Instruction Manual | Temperature Controllers | HD6 Instruction manual |
| 1 | CAD > 2D | Temperature Controllers | HD6 (2D) |