ED6

HANYOUNG NUX Electricals Temperature Controller

ED6

ED6 is a Hanyoung NUX temperature controllers for temperature measurement and control. Key specifications include Input: K, Pt 100 Ω, 4 - 20 mA d.c., 1 - 5 V d.c.; Control output: Relay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load).
  • Brand HANYOUNG NUX
  • Category Electricals
  • Subcategory Temperature Controller
Interested in this product? ED6
Product insights

Everything you need to evaluate this product

Explore performance details, construction highlights, applications, and technical information in one clear overview.

Quality assured Technical details Industrial use Expert support

Product Overview

ED6 is a Hanyoung NUX temperature controller for monitoring and regulating process temperature. The available configuration is built around the listed sensor inputs, control method and output arrangement, with model information of ED6. Control output: Relay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load); Indicate accuracy: ± 0.5 % of FS ± 1 Digit; Setting method: Digital type manipulated by setting, increase and decrease buttons.

For panel and process selection, the important characteristics are the input sensor type, control response, power requirements and display or communication options. Weight: 116 g; Ambient temperature & humidity: 0 ℃ ~ 50 ℃ / 35 ~ 85 % RH (condensation).

Key Features

Key strengths of the ED6 come from the combination of its functional configuration and practical installation specifications. The following characteristics highlight the values that matter most when comparing the product with equipment requirements.

Input: K, Pt 100 Ω, 4 - 20 mA d.c., 1 - 5 V d.c.; Control output: Relay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load); Indicate accuracy: ± 0.5 % of FS ± 1 Digit; Setting method: Digital type manipulated by setting, increase and decrease buttons.

  • Input: K, Pt 100 Ω, 4 - 20 mA d.c., 1 - 5 V d.c.
  • Control output: Relay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load)
  • Indicate accuracy: ± 0.5 % of FS ± 1 Digit
  • Setting method: Digital type manipulated by setting, increase and decrease buttons

Technical Characteristics

The ED6 is specified by its sensor input, control output, electrical supply, sampling behaviour and accuracy. These values determine how the controller measures temperature and applies its selected control response. Input: K, Pt 100 Ω, 4 - 20 mA d.c., 1 - 5 V d.c.; Control output: Relay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load); Indicate accuracy: ± 0.5 % of FS ± 1 Digit; Setting method: Digital type manipulated by setting, increase and decrease buttons.

Additional technical characteristics include .

Design and Construction

The physical design of ED6 should be considered together with the installation environment and the available mounting or display arrangement. Input: K, Pt 100 Ω, 4 - 20 mA d.c., 1 - 5 V d.c.; Control output: Relay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load); Indicate accuracy: ± 0.5 % of FS ± 1 Digit; Setting method: Digital type manipulated by setting, increase and decrease buttons.

Further construction and environmental details include .

Integration and Operation

Integration of ED6 requires the correct sensor input, control output, supply voltage and configuration settings for the application. Input: K, Pt 100 Ω, 4 - 20 mA d.c., 1 - 5 V d.c.; Control output: Relay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load); Indicate accuracy: ± 0.5 % of FS ± 1 Digit; Setting method: Digital type manipulated by setting, increase and decrease buttons.

Additional operating and interface details include . These values provide a practical reference for wiring, setup and normal operation within the selected configuration.

Selection and Use

Choose ED6 by confirming the exact model or configuration against the required operating conditions. The available model information is ED6. Input: K, Pt 100 Ω, 4 - 20 mA d.c., 1 - 5 V d.c.; Control output: Relay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load); Indicate accuracy: ± 0.5 % of FS ± 1 Digit; Setting method: Digital type manipulated by setting, increase and decrease buttons.

Before installation, confirm . Matching the model, electrical ratings, signal requirements, physical arrangement and environmental limits helps keep the product within its specified operating conditions.

SpecificationDetails
everyone VoltageAC power type | 100 - 240 V ~ 50/60 Hz
DC power type10 - 24 V d.c., Class2
voltage change rate± 10 % of supply voltage
Consumption powerAC power type | 10.0 VA or less
DC power type2.0 VA or less
InputK, Pt 100 Ω, 4 - 20 mA d.c., 1 - 5 V d.c.
Indicate accuracy± 0.5 % of FS ± 1 Digit
Control outputRelay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load)
SSR10 - 15 V d.c. (Load resistance 500Ω or more) , Approx. 20 mA V d.c. Max
Alarm/DefrostRelay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load)
Control actingReverse acting (heating) or direct acting (cooling)
Setting methodDigital type manipulated by setting, increase and decrease buttons
Additional featuresAlarm & Defrost
Wire resistanceThermo couple | Below 100 Ω round trip.
R.T.DBelow 10 Ω for each wire (Resistance of 3 wires should be the same.)
Ambient temperature & humidity0 ℃ ~ 50 ℃ / 35 ~ 85 % RH (condensation)
Weight116 g
NoType | Category | Title | File
1Manual > Instruction Manual | Temperature Controllers | ED6 Instruction manual
2Manual > Instruction Manual | Temperature Controllers | ED6 Instruction manual (old)
1CAD > 2D | Temperature Controllers | BR6,ED6,HD6 (2D)
NoMark | Category | Title | File
1Certification > CE | Temperature Controllers | ED6 (LVD)
2Certification > CE | Temperature Controllers | ED6, BR6 (EMC)
Contact setup1 c, 250 V a.c., 5 A (resistive load)
Shop by category
Category

Browse product families and jump into the exact catalog section you need.

Product categories