Explore performance details, construction highlights, applications, and technical information in one clear overview.
ED6 is a Hanyoung NUX temperature controller for monitoring and regulating process temperature. The available configuration is built around the listed sensor inputs, control method and output arrangement, with model information of ED6. Control output: Relay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load); Indicate accuracy: ± 0.5 % of FS ± 1 Digit; Setting method: Digital type manipulated by setting, increase and decrease buttons.
For panel and process selection, the important characteristics are the input sensor type, control response, power requirements and display or communication options. Weight: 116 g; Ambient temperature & humidity: 0 ℃ ~ 50 ℃ / 35 ~ 85 % RH (condensation).
Key strengths of the ED6 come from the combination of its functional configuration and practical installation specifications. The following characteristics highlight the values that matter most when comparing the product with equipment requirements.
Input: K, Pt 100 Ω, 4 - 20 mA d.c., 1 - 5 V d.c.; Control output: Relay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load); Indicate accuracy: ± 0.5 % of FS ± 1 Digit; Setting method: Digital type manipulated by setting, increase and decrease buttons.
The ED6 is specified by its sensor input, control output, electrical supply, sampling behaviour and accuracy. These values determine how the controller measures temperature and applies its selected control response. Input: K, Pt 100 Ω, 4 - 20 mA d.c., 1 - 5 V d.c.; Control output: Relay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load); Indicate accuracy: ± 0.5 % of FS ± 1 Digit; Setting method: Digital type manipulated by setting, increase and decrease buttons.
Additional technical characteristics include .
The physical design of ED6 should be considered together with the installation environment and the available mounting or display arrangement. Input: K, Pt 100 Ω, 4 - 20 mA d.c., 1 - 5 V d.c.; Control output: Relay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load); Indicate accuracy: ± 0.5 % of FS ± 1 Digit; Setting method: Digital type manipulated by setting, increase and decrease buttons.
Further construction and environmental details include .
Integration of ED6 requires the correct sensor input, control output, supply voltage and configuration settings for the application. Input: K, Pt 100 Ω, 4 - 20 mA d.c., 1 - 5 V d.c.; Control output: Relay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load); Indicate accuracy: ± 0.5 % of FS ± 1 Digit; Setting method: Digital type manipulated by setting, increase and decrease buttons.
Additional operating and interface details include . These values provide a practical reference for wiring, setup and normal operation within the selected configuration.
Choose ED6 by confirming the exact model or configuration against the required operating conditions. The available model information is ED6. Input: K, Pt 100 Ω, 4 - 20 mA d.c., 1 - 5 V d.c.; Control output: Relay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load); Indicate accuracy: ± 0.5 % of FS ± 1 Digit; Setting method: Digital type manipulated by setting, increase and decrease buttons.
Before installation, confirm . Matching the model, electrical ratings, signal requirements, physical arrangement and environmental limits helps keep the product within its specified operating conditions.
| Specification | Details |
|---|---|
| everyone Voltage | AC power type | 100 - 240 V ~ 50/60 Hz |
| DC power type | 10 - 24 V d.c., Class2 |
| voltage change rate | ± 10 % of supply voltage |
| Consumption power | AC power type | 10.0 VA or less |
| DC power type | 2.0 VA or less |
| Input | K, Pt 100 Ω, 4 - 20 mA d.c., 1 - 5 V d.c. |
| Indicate accuracy | ± 0.5 % of FS ± 1 Digit |
| Control output | Relay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load) |
| SSR | 10 - 15 V d.c. (Load resistance 500Ω or more) , Approx. 20 mA V d.c. Max |
| Alarm/Defrost | Relay | Contact setup : 1 c, 250 V a.c., 5 A (resistive load) |
| Control acting | Reverse acting (heating) or direct acting (cooling) |
| Setting method | Digital type manipulated by setting, increase and decrease buttons |
| Additional features | Alarm & Defrost |
| Wire resistance | Thermo couple | Below 100 Ω round trip. |
| R.T.D | Below 10 Ω for each wire (Resistance of 3 wires should be the same.) |
| Ambient temperature & humidity | 0 ℃ ~ 50 ℃ / 35 ~ 85 % RH (condensation) |
| Weight | 116 g |
| No | Type | Category | Title | File |
| 1 | Manual > Instruction Manual | Temperature Controllers | ED6 Instruction manual |
| 2 | Manual > Instruction Manual | Temperature Controllers | ED6 Instruction manual (old) |
| 1 | CAD > 2D | Temperature Controllers | BR6,ED6,HD6 (2D) |
| No | Mark | Category | Title | File |
| 1 | Certification > CE | Temperature Controllers | ED6 (LVD) |
| 2 | Certification > CE | Temperature Controllers | ED6, BR6 (EMC) |
| Contact setup | 1 c, 250 V a.c., 5 A (resistive load) |