The TD2933 is an IFM temperature transmitter with an integrated display for dependable temperature monitoring in industrial and hygienic processes. Its Pt 1000 Class A sensor provides stable and repeatable temperature measurement. The 100 mm installation length provides suitable immersion for process piping and vessels. A 4–20 mA output enables standard automation integration while IO-Link provides digital communication and diagnostics. The transmitter is designed for demanding process applications where local display and remote temperature feedback are both required.
Explore performance details, construction highlights, applications, and technical information in one clear overview.
The TD2933 features a 100 mm sensing length with integrated transmitter electronics. Stainless-steel construction provides mechanical strength and suitable process compatibility. Its integrated display allows local temperature checking without additional instruments. The process connection supports compatible hygienic installations. The M12 connector provides a compact industrial electrical interface. The design is suitable for continuous use in automated process equipment.
The Pt 1000 Class A sensing element provides reliable temperature measurement. The 100 mm insertion length gives useful sensing depth for process vessels and piping. The FF configuration supports the corresponding Fahrenheit-oriented application range. A 4–20 mA output provides a standard analogue signal. IO-Link enables digital configuration and diagnostic functions. Fast response helps the transmitter follow changes in process temperature.
The four-digit display provides convenient local temperature indication. Celsius and Fahrenheit presentation supports different plant requirements. The M12 A-coded connector supports reliable automation wiring. IO-Link enables digital communication with compatible control systems. The 4–20 mA output supports traditional PLC analogue inputs. The combination makes the transmitter suitable for mixed automation architectures.
The TD2933 is suitable for food, beverage and process applications requiring a 100 mm sensing length. It can be installed in piping, tanks, vessels and process skids. Stainless-steel construction supports suitable hygienic applications. High ingress protection helps protect the transmitter in industrial environments. The integrated display simplifies commissioning and operator monitoring. Correct process selection is required for pressure, temperature and media compatibility.
100 mm probe length
Pt 1000 Class A
Integrated 4-digit display
4–20 mA output
IO-Link 1.1
COM2
M12 A-coded connector
°C / °F indication
Stainless-steel housing
Fast response
High ingress protection
Local indication
Digital diagnostics
PLC integration
Industrial automation
Food processing
Beverage production
Dairy systems
Brewing equipment
Process tanks
Process vessels
Sanitary piping
CIP equipment
Filling machines
Packaging systems
Liquid monitoring
Gas monitoring
Thermal processing
PLC systems
Process automation
| Specification | Details |
|---|---|
| Product Model | TD2933 |
| Type Code | TD-100FFEC02-A-ZVG/US |
| Sensor | Pt 1000 Class A |
| Standard | DIN EN 60751 |
| Nominal Range | -50...150 °C |
| Factory Configuration | 0...300 °F |
| Installation Length | 100 mm |
| Probe Diameter | Approx. 6 mm |
| Process Connection | Hygienic clamp |
| Display | 4-digit LED |
| Display Technology | 7-segment |
| Display Units | °C / °F |
| Analogue Output | 4–20 mA |
| Communication | IO-Link 1.1 |
| Mode | COM2 |
| Baud Rate | 38.4 kBaud |
| Supply | 18...32 V DC |
| Current Consumption | <50 mA |
| Electrical Connection | M12 A-coded |
| Protection Class | III |
| Protection Rating | IP67 / IP68 / IP69K |
| Wetted Material | 316L / 1.4404 |
| Sensor Principle | RTD |
| Installation | Process mounted |
| Local Display | Integrated |