The TD2841 is a 150 mm hygienic temperature transmitter designed for deeper temperature measurement in process vessels and piping. It uses a Pt1000 Class A sensor and provides direct local indication through a four-digit LED display. The transmitter supports 4–20 mA analogue output and IO-Link communication for automation integration. Its sanitary clamp connection provides hygienic installation for food and beverage equipment. The long 150 mm probe provides improved flexibility for deeper process measurement points.
Explore performance details, construction highlights, applications, and technical information in one clear overview.
TD2841 is suitable for applications requiring extended probe insertion. The 150 mm length provides deeper sensing capability. The integrated display supports local process monitoring. IO-Link provides digital setup and diagnostics. The device is suitable for continuous industrial operation.
The Pt1000 sensor provides stable process measurement. The measuring range extends from -50...150 °C. The 4–20 mA signal supports PLC inputs. IO-Link provides digital process communication. Fast response supports dynamic temperature changes.
The clamp connection is suitable for sanitary process installations. Stainless-steel wetted parts provide robust process compatibility. Electropolished surfaces support hygienic cleaning. The 150 mm installation length suits larger process vessels. High ingress protection supports washdown environments.
IO-Link supports configuration and diagnostic access. The local display helps maintenance personnel confirm measured temperature. Electrical protection supports dependable operation. Stainless-steel construction supports repeated cleaning. Inspection of seals and clamp connections helps maintain process integrity.
150 mm probe
Pt1000 Class A
-50...150 °C range
4-digit LED display
4–20 mA output
IO-Link
Sanitary clamp
316L stainless steel
Electropolished wetted parts
IP67/IP68/IP69K
Large tanks
Process vessels
Food production
Dairy processing
Brewing
Beverage manufacturing
Pipeline temperature monitoring
PLC control
CIP systems
Industrial automation
| No. | Specification | Details |
|---|---|---|
| 1 | Product Code | TD2841 |
| 2 | Product Type | Hygienic temperature transmitter |
| 3 | Measuring Element | Pt1000 |
| 4 | Sensor Class | Class A |
| 5 | Measuring Range | -50...150 °C |
| 6 | Factory Setting | -10...150 °C |
| 7 | Installation Length | 150 mm |
| 8 | Probe Diameter | 6 mm |
| 9 | Process Connection | Clamp |
| 10 | Standard | DIN 32676 / ISO 2852 |
| 11 | Connection Size | DN25...DN40 / 1...1.5 in |
| 12 | Output | 4–20 mA |
| 13 | Maximum Load | 300 Ω |
| 14 | Communication | IO-Link |
| 15 | IO-Link Revision | 1.1 |
| 16 | Supply Voltage | 18–32 V DC |
| 17 | Current Consumption | <50 mA |
| 18 | Display | 4-digit LED |
| 19 | Display Units | °C / °F |
| 20 | Analogue Resolution | 0.04 K |
| 21 | Display Resolution | 0.1 K |
| 22 | Dynamic Response | T05/T09 1/3 s |
| 23 | Ambient Temperature | -25...80 °C |
| 24 | Storage Temperature | -40...100 °C |
| 25 | Protection | IP67 / IP68 / IP69K |