TA2247 is a 150 mm temperature transmitter with a Pt1000 Class A sensing element. It supports a −50…200 °C measurement range and a 0…100 °C factory setting. The transmitter provides a scalable 4–20 mA output and IO-Link communication. Its Ø6 mm probe is designed for installation through a clamp adapter. TA2247 is suitable for process temperature monitoring in industrial and hygienic equipment.
Explore performance details, construction highlights, applications, and technical information in one clear overview.
TA2247 is designed for process applications requiring a 150 mm sensing depth and a factory range optimized for moderate temperatures. The Pt1000 Class A element provides accurate temperature measurement. The 4–20 mA output integrates with industrial controllers. IO-Link allows parameterisation and digital process monitoring. The stainless-steel construction provides durability.
The Pt1000 element detects temperature through resistance changes. Electronics convert the resistance into a process temperature value. The analogue output provides a proportional 4–20 mA signal. IO-Link provides digital communication and configuration. Continuous temperature measurement supports process automation.
The sensor uses a stainless-steel housing and 6 mm probe. The clamp adapter supports secure process installation. High IP protection supports wet and demanding environments. Shock and vibration resistance provide mechanical robustness. The transmitter is suitable for continuous industrial operation.
Pt1000 Class A
−50…200 °C
0…100 °C factory setting
150 mm installation length
Ø6 mm probe
4–20 mA
IO-Link
COM2
M12 connection
Stainless steel
0.04 K resolution
±0.3 K + ±0.1% MS accuracy
Fast response
IP67/IP68/IP69K
50 g shock resistance
10 g vibration resistance
PLC integration
Digital diagnostics
Temperature monitoring
Process tanks
Pipelines
Industrial machinery
Pump systems
Process control
Plant engineering
OEM equipment
PLC automation
SCADA systems
Temperature alarms
Equipment protection
Maintenance
Process quality control
Industrial automation
| Specification | Details |
|---|---|
| Product model | TA2247 |
| Order code | TA-150CLED06--/US |
| Sensor | Pt1000 Class A |
| Measuring range | −50…200 °C |
| Factory setting | 0…100 °C |
| Installation length | 150 mm |
| Probe diameter | 6 mm |
| Process connection | Clamp adapter Ø6 mm |
| Media | Liquids and gases |
| Pressure rating | 160 bar |
| Vacuum resistance | −1000 mbar |
| Output | 4–20 mA |
| Output type | Scalable |
| Communication | IO-Link |
| IO-Link revision | 1.1 |
| Transmission | COM2 |
| Supply | 18–32 V DC |
| Resolution | 0.04 K |
| Accuracy | ±0.3 K + ±0.1% MS |
| Response T05/T09 | <0.5 / <2 s |
| Ambient | −25…80 °C |
| Storage | −40…100 °C |
| Protection | IP67/IP68/IP69K |
| Connection | M12 |
| Housing | Stainless steel |