This pressure switch features an adjustment range of 0.2–2 bar, a max static pressure rating of 350 bar, and operates within 220 VAC working voltage. It delivers reliable performance with a 100/1 minute cycle rate and IP65 protection for harsh environments.
This pressure switch provides accurate pressure detection with a fixed adjustment range of 0.2–2 bar, robust construction for static pressure up to 350 bar, and reliable operation under 220 VAC working conditions. Its IP65 protection ensures suitability for harsh industrial environments, while the 100/1 minute cycle rate and low hysteresis (30% of set-point) make it ideal for critical pressure control systems.
It operates with a working voltage of 220 VAC, current ratings of 3 A (resistive) and 2 A (inductive), and a max static pressure of 350 bar. The switch includes an adjustment range of 0.2–2 bar, a cycle rate of 100/1 minute, and a hysteresis tolerance of 30% of set-point (or 10% F.S.) at 25°C. Its IP65 protection ensures robust performance in dusty or wet environments, while the 250 VAC, 24 VDC, and 30 V with 'G' option provide flexible power compatibility.
This pressure switch functions optimally at 25°C with a tolerance of ±0.15 bar for the adjustment range. It supports a maximum static pressure of 350 bar and operates within a 220 VAC working voltage range. The PMC10DFC14KHSGM12- Pressure switch with SPDT contacts is designed for environments with high dust and moisture levels, as indicated by its IP65 rating. The 100/1 minute cycle rate ensures reliable performance without overheating or mechanical wear.
Its robust construction and IP65 protection make it suitable for use in harsh environments like manufacturing plants, oil and gas facilities, and chemical processing units where pressure stability is critical.
The ELETTROTEC PMC10DFC14KHSGM12- Pressure switch with SPDT contacts- Pressure switch with SPDT contacts is an industrial Pressure. Selection should be based on the documented characteristics and the requirements of the intended application.
| Feature | Specification |
|---|---|
| Dimensions | Body 30 x 30 – Max. high75 mm |
| Maximum voltage 250 Vac, 24 Vdc; 30 V with option “G” | Max. voltage 250 Vac, 24 Vdc; 30 V with “G” option |
| Working voltage 220 Vac | Working voltage 220 Vac |
| Current intensity 3 A (resistive), 2 A (inductive) | Current 3 A (resistive), 2 A (inductive) |
| Fixed differential max. 25°C 30% of the set-point value di set-point (o 10% F.S.) | Max. fixed hysteresis at 25°C 30% of set-point (or 10% F.S.) |
| Current maximum / Max. current | < 30 mA |
| Switch rating | 250 Vac, 24 Vdc; 30 V with “G” option / 3 (2) A |
| Adjustment range | 0.2 – 2 bar – 0.5 – 5 bar – 1 -10 bar – 5 – 25 bar – 25 – 80 bar |
| Max. static pressure | 350 bar |