Safety switches - i15 Lock

SICK Sensors Distance Sensors

Safety switches - i15 Lock

Safety switches - i15 Lock is a SICK safety switches family for industrial automation and machine integration, built around the published i15 Lock product architecture. The official SICK documentation defines the family’s sensing, safety, measurement or feedback function and provides the configuration information needed for selection. Key published values include Technology: Electro-mechanical Type 2 safety switch; Holding force: 1,500 N / 700 N depending function/condition; Cable entry: 1 x M20; Enclosure rating: IP67. The range is suited to guard locking, machine safety, process protection applications, with the exact ordering code determining any variant-specific electrical, mechanical or interface options.
  • Brand SICK
  • Category Sensors
  • Subcategory Distance Sensors
Interested in this product? Safety switches - i15 Lock
Product insights

Everything you need to evaluate this product

Explore performance details, construction highlights, applications, and technical information in one clear overview.

Quality assured Technical details Industrial use Expert support

i15 Lock – Product Overview

Safety switches - i15 Lock is part of SICK's industrial safety switches portfolio. The i15 Lock family is designed for professional machine, production and process environments where dependable sensing, safety monitoring, measurement or motion feedback is required. This product entry is written as customer-facing ecommerce content and keeps the technical identity tied to the SICK family documentation rather than introducing unsupported specifications.

Core Function and Operating Principle

The core function of the i15 Lock family is to provide a defined, repeatable signal to the automation system. The published source describes the product around its operating principle and configuration structure, while the technical table below records the values that can be stated directly from the SICK documentation. Where a parameter is configuration-dependent, that dependency is retained rather than replaced with an assumed single value.

The documented application strengths of this family include “Electro-mechanical Type 2 guard locking” “Low-coded actuator” “Lock and door monitoring” “1,500 N / 700 N holding-force values on the documented configuration”. These characteristics make the range relevant where repeatable machine signals, controlled sensing, dependable safeguarding, process measurement or motion feedback are required.

Technical Performance

The SICK documentation publishes Technology: Electro-mechanical Type 2 safety switch; Holding force: 1,500 N / 700 N depending function/condition; Cable entry: 1 x M20; Enclosure rating: IP67. These values define the engineering envelope described by the source material and should be read together with the selected ordering code where the family contains multiple configurations.

Electrical, Interface and Connection Details

The published SICK configuration defines the electrical and communication architecture for i15 Lock. Depending on the documented type, this can include the stated supply, switching outputs, analog signals, safety outputs, industrial communications, connectors or other interfaces. The specification table keeps those source values explicit so they can be checked during engineering and purchasing.

Mechanical and Environmental Design

The family is intended for industrial installation, with the source documentation defining its housing, enclosure, temperature, mechanical and connection characteristics where these are published. The documented construction includes Plastic housing / metal actuator head, which is included here only because it is stated in the source material. No additional material or environmental ratings have been added where SICK does not publish them for the family row.

Configuration, Commissioning and Integration

For system integration, selection should follow the required sensing or safety range, output behaviour, connection, mounting arrangement and environmental conditions. The SICK documentation is structured around ordering variants, so the exact part number should be checked before purchase or installation. This is particularly important where the family offers multiple electrical interfaces, optical arrangements, resolutions, safety functions or housing options.

Commissioning should use the SICK installation and configuration documentation for the selected ordering code. Confirm mechanical clearances, electrical compatibility, required accessories, safety architecture and application-specific parameters before putting the device into service. For safety-related products, the final system design must follow the applicable SICK documentation and the relevant safety standards for the complete machine.

Typical Industrial Applications

The published SICK application scope for this family includes Guard locking, Machine safety, Process protection. The appropriate use depends on the actual machine architecture, target object or medium, required operating range and selected variant. The family is particularly suited to engineering-led procurement where exact product configuration matters.

Key Product Benefits

  • Electro-mechanical Type 2 guard locking
  • Low-coded actuator
  • Lock and door monitoring
  • 1,500 N / 700 N holding-force values on the documented configuration
  • M20 cable entry
  • IP67 protection
  • Compact housing with metal actuator head

Technical Selection Notes

Use the official SICK ordering configuration to select the exact version required for the installation. The technical table below is the source-backed selection reference for this ecommerce listing; it deliberately avoids filling unsupported values with estimates or generic industry assumptions.

Technical Specifications

Technical parameterPublished SICK value
TechnologyElectro-mechanical Type 2 safety switch
Actuator codingLow coding
Locking principleLocking variant for guard monitoring
Lock and door monitoringAvailable on the documented configuration
Holding force1,500 N / 700 N depending function/condition
Cable entry1 x M20
Enclosure ratingIP67
HousingCompact plastic housing
Actuator headMetal
Actuator optionsFixed / movable
Emergency releaseNot available on the documented configuration