PAS series

HANYOUNG NUX Electricals Encoder

PAS series

PAS series is a Hanyoung NUX area sensor for area-based object detection. Key specifications include Sensing distance: ▪Cross-beam : 0.5 ~ 5 m ▪Parallel-beam : 0.1 ~ 5 m; Control output: ▪NPN / PNP open collector output ▪Load Current: Max. 100mA (26.4 V d.c. standard) ▪Residual voltage - NPN : Max. 1 V, PNP : Max. 2 V.
  • Brand HANYOUNG NUX
  • Category Electricals
  • Subcategory Encoder
Interested in this product? PAS series
Product insights

Everything you need to evaluate this product

Explore performance details, construction highlights, applications, and technical information in one clear overview.

Quality assured Technical details Industrial use Expert support

Product Overview

PAS series is a Hanyoung NUX area sensor for non-contact detection and machine sensing. The configuration is defined by its sensing method, sensing range, output arrangement and electrical requirements, with model information of Cross beam (PAS-M) | Light ON | NPN | PAS- M4NL | PAS- M8NL | PAS- M12NL | PAS- M16NL. Sensing width: 60 mm | 140 mm | 220 mm | 300 mm; Sensing width: 380 mm | 460 mm | 540 mm; Sensing distance: ▪Cross-beam : 0.5 ~ 5 m ▪Parallel-beam : 0.1 ~ 5 m; Sensing object: ▪Cross-beam : Opaque object over Ø20 mm (Center 75% of the area between the transmitter and receiver).

The sensing distance, target object, response time, output type and environmental limits are the key details to compare when selecting the sensor for a specific machine or detection point. Light source: IR (850nm); Operation mode: Light On or Dark On; Connection method: cable withdrawal type (Number of wires : 5P, Code length : 3m , Dimension : Ø4mm); weight(g): 160 | 180 | 200 | 220.

Key Features

Key strengths of the PAS series come from the combination of its functional configuration and practical installation specifications. The following characteristics highlight the values that matter most when comparing the product with equipment requirements.

Sensing distance: ▪Cross-beam : 0.5 ~ 5 m ▪Parallel-beam : 0.1 ~ 5 m; Control output: ▪NPN / PNP open collector output ▪Load Current: Max. 100mA (26.4 V d.c. standard) ▪Residual voltage - NPN : Max. 1 V, PNP : Max. 2 V; Response Time: ▪Cross-beam : 15 ms or less when light blocked, 30 ms or less when light received ▪Parallel-beam : both 10 ms or less when light blocked/received; Degree of protection: IP40; Ambient temperature: During operation : -10 ~ +55 ℃, During storage : -25 ~ +70 ℃ (Without condensation or icing).

  • Sensing distance: ▪Cross-beam : 0.5 ~ 5 m ▪Parallel-beam : 0.1 ~ 5 m
  • Control output: ▪NPN / PNP open collector output ▪Load Current: Max. 100mA (26.4 V d.c. standard) ▪Residual voltage - NPN : Max. 1 V, PNP : Max. 2 V
  • Response Time: ▪Cross-beam : 15 ms or less when light blocked, 30 ms or less when light received ▪Parallel-beam : both 10 ms or less when light blocked/received
  • Degree of protection: IP40
  • Ambient temperature: During operation : -10 ~ +55 ℃, During storage : -25 ~ +70 ℃ (Without condensation or icing)
  • Sensing width: 60 mm | 140 mm | 220 mm | 300 mm
  • Sensing width: 380 mm | 460 mm | 540 mm
  • Sensing object: ▪Cross-beam : Opaque object over Ø20 mm (Center 75% of the area between the transmitter and receiver)
  • Current consumption: Max. 80 mA | Max. 90 mA | Max. 100 mA | Max. 110 mA
  • Current consumption: Max. 120 mA | Max. 130 mA | Max. 140 mA

Technical Characteristics

The PAS series technical profile is centred on sensing method, detection range, target characteristics, output behaviour and response time. These parameters define the sensor's operating window and electrical interface. Control output: ▪NPN / PNP open collector output ▪Load Current: Max. 100mA (26.4 V d.c. standard) ▪Residual voltage - NPN : Max. 1 V, PNP : Max. 2 V; Response Time: ▪Cross-beam : 15 ms or less when light blocked, 30 ms or less when light received ▪Parallel-beam : both 10 ms or less when light blocked/received; Current consumption: Max. 80 mA | Max. 90 mA | Max. 100 mA | Max. 110 mA; Current consumption: Max. 120 mA | Max. 130 mA | Max. 140 mA.

Additional technical characteristics include Power voltage: 12 - 24 V d.c. ±10% Ripple(p-p) 10% Max; Protection circuit: Power reverse connection protection, Output short-circuit over-current protection, Mutual interference prevation function; Insulation resistance: Min. 20 MΩ (500 V d.c. mega standard).

Design and Construction

The physical design of PAS series should be considered together with the installation environment and the available mounting or display arrangement. weight(g): 240 | 260 | 280; Lens: PMMA; cable withdrawal type (Number of wires: 5P, Code length : 3m , Dimension : Ø4mm); Noise immunity: Square wave noise by noise simulator (pulse width 1 µs) ± 240 V d.c..

Further construction and environmental details include Dielectric strength: 1,000 V a.c. (50/60 ㎐ 1min); Vibration resistance: 10 ~ 55 Hz, sweep : 1.5 mm, X·Y·Z in each direction for 2 hours; Shock resistance: 500 m/s², X·Y·Z each direction 3 times.

Integration and Operation

Integration of PAS series starts with matching its sensing method, supply voltage, output type and connection method to the control system. Sensing distance: ▪Cross-beam : 0.5 ~ 5 m ▪Parallel-beam : 0.1 ~ 5 m; Control output: ▪NPN / PNP open collector output ▪Load Current: Max. 100mA (26.4 V d.c. standard) ▪Residual voltage - NPN : Max. 1 V, PNP : Max. 2 V; Response Time: ▪Cross-beam : 15 ms or less when light blocked, 30 ms or less when light received ▪Parallel-beam : both 10 ms or less when light blocked/received; Degree of protection: IP40.

Additional operating and interface details include Ambient temperature: During operation : -10 ~ +55 ℃, During storage : -25 ~ +70 ℃ (Without condensation or icing); Sensing width: 60 mm | 140 mm | 220 mm | 300 mm; Sensing width: 380 mm | 460 mm | 540 mm. These values provide a practical reference for wiring, setup and normal operation within the selected configuration.

Selection and Use

Choose PAS series by confirming the exact model or configuration against the required operating conditions. The available model information is Cross beam (PAS-M) | Light ON | NPN | PAS- M4NL | PAS- M8NL | PAS- M12NL | PAS- M16NL. Model: Cross beam (PAS-M) | Light ON | NPN | PAS- M4NL | PAS- M8NL | PAS- M12NL | PAS- M16NL; Model: Cross- beam (PAS-M) | Light ON | NPN | PAS- M20NL | PAS- M24NL | PAS- M28NL; Ambient temperature: During operation : -10 ~ +55 ℃, During storage : -25 ~ +70 ℃ (Without condensation or icing); Ambient humidity: 35 ~ 85 % RH (Without condensation).

Before installation, confirm Degree of protection: IP40. Matching the model, electrical ratings, signal requirements, physical arrangement and environmental limits helps keep the product within its specified operating conditions.

SpecificationDetails
ModelCross beam (PAS-M) | Light ON | NPN | PAS- M4NL | PAS- M8NL | PAS- M12NL | PAS- M16NL
PNPPAS- M4PL | PAS- M8PL | PAS- M12PL | PAS- M16PL
Dark ONNPN | PAS- M4ND | PAS- M8ND | PAS- M12ND | PAS- M16ND
PNPPAS- M4PD | PAS- M8PD | PAS- M12PD | PAS- M16PD
Parallel beam (PAS-T)Light ON | NPN | PAS- T4NL | PAS- T8NL | PAS- T12NL | PAS- T16NL
PNPPAS- T4PL | PAS- T8PL | PAS- T12PL | PAS- T16PL
Dark ONNPN | PAS- T4ND | PAS- T8ND | PAS- T12ND | PAS- T16ND
PNPPAS- T4PD | PAS- T8PD | PAS- T12PD | PAS- T16PD
Number of optical axis4 | 8 | 12 | 16
Sensing width60 mm | 140 mm | 220 mm | 300 mm
Current consumptionMax. 80 mA | Max. 90 mA | Max. 100 mA | Max. 110 mA
weight(g)160 | 180 | 200 | 220
ModelCross- beam (PAS-M) | Light ON | NPN | PAS- M20NL | PAS- M24NL | PAS- M28NL
PNPPAS- M20PL | PAS- M24PL | PAS- M28PL
Dark ONNPN | PAS- M20ND | PAS- M24ND | PAS- M28ND
PNPPAS- M20PD | PAS- M24PD | PAS- M28PD
Parallel- beam (PAS-T)Light ON | NPN | PAS- T20NL | PAS- T24NL | PAS- T28NL
PNPPAS- T20PL | PAS- T24PL | PAS- T28PL
Dark ONNPN | PAS- T20ND | PAS- T24ND | PAS- T28ND
PNPPAS- T20PD | PAS- T24PD | PAS- T28PD
Number of optical axis20 | 24 | 28
Sensing width380 mm | 460 mm | 540 mm
Current consumptionMax. 120 mA | Max. 130 mA | Max. 140 mA
weight(g)240 | 260 | 280
Detection Methods▪Cross-beam(PAS-M) : Transmissive 3-point cross-beam detection method
Sensing distance▪Cross-beam : 0.5 ~ 5 m ▪Parallel-beam : 0.1 ~ 5 m
Sensing object▪Cross-beam : Opaque object over Ø20 mm (Center 75% of the area between the transmitter and receiver)
Optical axis pitch20 mm
Light sourceIR (850nm)
Power voltage12 - 24 V d.c. ±10% Ripple(p-p) 10% Max
Control output▪NPN / PNP open collector output ▪Load Current: Max. 100mA (26.4 V d.c. standard) ▪Residual voltage - NPN : Max. 1 V, PNP : Max. 2 V
Operation modeLight On or Dark On
Operation LED▪Transmitter : Power indicator(Green LED), M/S display(Red LED) ▪Receiver : Light on stability display(Green LED), Output Display(Red LED), E1 display(Red LED), Power indicator (Blue LED)
Protection circuitPower reverse connection protection, Output short-circuit over-current protection, Mutual interference prevation function
Response Time▪Cross-beam : 15 ms or less when light blocked, 30 ms or less when light received ▪Parallel-beam : both 10 ms or less when light blocked/received
Insulation resistanceMin. 20 MΩ (500 V d.c. mega standard)
Noise immunitySquare wave noise by noise simulator (pulse width 1 µs) ± 240 V d.c.
Dielectric strength1,000 V a.c. (50/60 ㎐ 1min)
Vibration resistance10 ~ 55 Hz, sweep : 1.5 mm, X·Y·Z in each direction for 2 hours
Shock resistance500 m/s², X·Y·Z each direction 3 times
Ambient illuminationSunlight : Max. 11,000 Lux, Incandescent lamp : Max. 3,000 Lux (Receiver illumination)
Ambient temperatureDuring operation : -10 ~ +55 ℃, During storage : -25 ~ +70 ℃ (Without condensation or icing)
Ambient humidity35 ~ 85 % RH (Without condensation)
Degree of protectionIP40
Connection methodcable withdrawal type (Number of wires : 5P, Code length : 3m , Dimension : Ø4mm)
Mate rialCase | ABS
Front CoverPMMA
LensPMMA
NoType | Category | Title | File
1Manual > Instruction Manual | Area Sensor | PAS series Instruction Manual
NoMark | Category | Title | File
1Certification > CE | Area Sensor | PAS / PAN series (EMC)
2Certification > CE | Area Sensor | PAS-M/T12 EMC (AoC)
3Certification > CE | Area Sensor | PAS-M/T16 EMC (AoC)
4Certification > CE | Area Sensor | PAS-M/T20 EMC (AoC)
5Certification > CE | Area Sensor | PAS-M/T24 EMC (AoC)
6Certification > CE | Area Sensor | PAS-M/T28 EMC (AoC)
7Certification > CE | Area Sensor | PAS-M/T4 EMC (AoC)
8Certification > CE | Area Sensor | PAS-M/T8 EMC (AoC)
▪Load CurrentMax. 100mA (26.4 V d.c. standard) ▪Residual voltage - NPN : Max. 1 V, PNP : Max. 2 V
10 ~ 55 Hz, sweep1.5 mm, X·Y·Z in each direction for 2 hours
During operation-10 ~ +55 ℃, During storage : -25 ~ +70 ℃ (Without condensation or icing)
cable withdrawal type (Number of wires5P, Code length : 3m , Dimension : Ø4mm)