Explore performance details, construction highlights, applications, and technical information in one clear overview.
PAS series is a Hanyoung NUX area sensor for non-contact detection and machine sensing. The configuration is defined by its sensing method, sensing range, output arrangement and electrical requirements, with model information of Cross beam (PAS-M) | Light ON | NPN | PAS- M4NL | PAS- M8NL | PAS- M12NL | PAS- M16NL. Sensing width: 60 mm | 140 mm | 220 mm | 300 mm; Sensing width: 380 mm | 460 mm | 540 mm; Sensing distance: ▪Cross-beam : 0.5 ~ 5 m ▪Parallel-beam : 0.1 ~ 5 m; Sensing object: ▪Cross-beam : Opaque object over Ø20 mm (Center 75% of the area between the transmitter and receiver).
The sensing distance, target object, response time, output type and environmental limits are the key details to compare when selecting the sensor for a specific machine or detection point. Light source: IR (850nm); Operation mode: Light On or Dark On; Connection method: cable withdrawal type (Number of wires : 5P, Code length : 3m , Dimension : Ø4mm); weight(g): 160 | 180 | 200 | 220.
Key strengths of the PAS series come from the combination of its functional configuration and practical installation specifications. The following characteristics highlight the values that matter most when comparing the product with equipment requirements.
Sensing distance: ▪Cross-beam : 0.5 ~ 5 m ▪Parallel-beam : 0.1 ~ 5 m; Control output: ▪NPN / PNP open collector output ▪Load Current: Max. 100mA (26.4 V d.c. standard) ▪Residual voltage - NPN : Max. 1 V, PNP : Max. 2 V; Response Time: ▪Cross-beam : 15 ms or less when light blocked, 30 ms or less when light received ▪Parallel-beam : both 10 ms or less when light blocked/received; Degree of protection: IP40; Ambient temperature: During operation : -10 ~ +55 ℃, During storage : -25 ~ +70 ℃ (Without condensation or icing).
The PAS series technical profile is centred on sensing method, detection range, target characteristics, output behaviour and response time. These parameters define the sensor's operating window and electrical interface. Control output: ▪NPN / PNP open collector output ▪Load Current: Max. 100mA (26.4 V d.c. standard) ▪Residual voltage - NPN : Max. 1 V, PNP : Max. 2 V; Response Time: ▪Cross-beam : 15 ms or less when light blocked, 30 ms or less when light received ▪Parallel-beam : both 10 ms or less when light blocked/received; Current consumption: Max. 80 mA | Max. 90 mA | Max. 100 mA | Max. 110 mA; Current consumption: Max. 120 mA | Max. 130 mA | Max. 140 mA.
Additional technical characteristics include Power voltage: 12 - 24 V d.c. ±10% Ripple(p-p) 10% Max; Protection circuit: Power reverse connection protection, Output short-circuit over-current protection, Mutual interference prevation function; Insulation resistance: Min. 20 MΩ (500 V d.c. mega standard).
The physical design of PAS series should be considered together with the installation environment and the available mounting or display arrangement. weight(g): 240 | 260 | 280; Lens: PMMA; cable withdrawal type (Number of wires: 5P, Code length : 3m , Dimension : Ø4mm); Noise immunity: Square wave noise by noise simulator (pulse width 1 µs) ± 240 V d.c..
Further construction and environmental details include Dielectric strength: 1,000 V a.c. (50/60 ㎐ 1min); Vibration resistance: 10 ~ 55 Hz, sweep : 1.5 mm, X·Y·Z in each direction for 2 hours; Shock resistance: 500 m/s², X·Y·Z each direction 3 times.
Integration of PAS series starts with matching its sensing method, supply voltage, output type and connection method to the control system. Sensing distance: ▪Cross-beam : 0.5 ~ 5 m ▪Parallel-beam : 0.1 ~ 5 m; Control output: ▪NPN / PNP open collector output ▪Load Current: Max. 100mA (26.4 V d.c. standard) ▪Residual voltage - NPN : Max. 1 V, PNP : Max. 2 V; Response Time: ▪Cross-beam : 15 ms or less when light blocked, 30 ms or less when light received ▪Parallel-beam : both 10 ms or less when light blocked/received; Degree of protection: IP40.
Additional operating and interface details include Ambient temperature: During operation : -10 ~ +55 ℃, During storage : -25 ~ +70 ℃ (Without condensation or icing); Sensing width: 60 mm | 140 mm | 220 mm | 300 mm; Sensing width: 380 mm | 460 mm | 540 mm. These values provide a practical reference for wiring, setup and normal operation within the selected configuration.
Choose PAS series by confirming the exact model or configuration against the required operating conditions. The available model information is Cross beam (PAS-M) | Light ON | NPN | PAS- M4NL | PAS- M8NL | PAS- M12NL | PAS- M16NL. Model: Cross beam (PAS-M) | Light ON | NPN | PAS- M4NL | PAS- M8NL | PAS- M12NL | PAS- M16NL; Model: Cross- beam (PAS-M) | Light ON | NPN | PAS- M20NL | PAS- M24NL | PAS- M28NL; Ambient temperature: During operation : -10 ~ +55 ℃, During storage : -25 ~ +70 ℃ (Without condensation or icing); Ambient humidity: 35 ~ 85 % RH (Without condensation).
Before installation, confirm Degree of protection: IP40. Matching the model, electrical ratings, signal requirements, physical arrangement and environmental limits helps keep the product within its specified operating conditions.
| Specification | Details |
|---|---|
| Model | Cross beam (PAS-M) | Light ON | NPN | PAS- M4NL | PAS- M8NL | PAS- M12NL | PAS- M16NL |
| PNP | PAS- M4PL | PAS- M8PL | PAS- M12PL | PAS- M16PL |
| Dark ON | NPN | PAS- M4ND | PAS- M8ND | PAS- M12ND | PAS- M16ND |
| PNP | PAS- M4PD | PAS- M8PD | PAS- M12PD | PAS- M16PD |
| Parallel beam (PAS-T) | Light ON | NPN | PAS- T4NL | PAS- T8NL | PAS- T12NL | PAS- T16NL |
| PNP | PAS- T4PL | PAS- T8PL | PAS- T12PL | PAS- T16PL |
| Dark ON | NPN | PAS- T4ND | PAS- T8ND | PAS- T12ND | PAS- T16ND |
| PNP | PAS- T4PD | PAS- T8PD | PAS- T12PD | PAS- T16PD |
| Number of optical axis | 4 | 8 | 12 | 16 |
| Sensing width | 60 mm | 140 mm | 220 mm | 300 mm |
| Current consumption | Max. 80 mA | Max. 90 mA | Max. 100 mA | Max. 110 mA |
| weight(g) | 160 | 180 | 200 | 220 |
| Model | Cross- beam (PAS-M) | Light ON | NPN | PAS- M20NL | PAS- M24NL | PAS- M28NL |
| PNP | PAS- M20PL | PAS- M24PL | PAS- M28PL |
| Dark ON | NPN | PAS- M20ND | PAS- M24ND | PAS- M28ND |
| PNP | PAS- M20PD | PAS- M24PD | PAS- M28PD |
| Parallel- beam (PAS-T) | Light ON | NPN | PAS- T20NL | PAS- T24NL | PAS- T28NL |
| PNP | PAS- T20PL | PAS- T24PL | PAS- T28PL |
| Dark ON | NPN | PAS- T20ND | PAS- T24ND | PAS- T28ND |
| PNP | PAS- T20PD | PAS- T24PD | PAS- T28PD |
| Number of optical axis | 20 | 24 | 28 |
| Sensing width | 380 mm | 460 mm | 540 mm |
| Current consumption | Max. 120 mA | Max. 130 mA | Max. 140 mA |
| weight(g) | 240 | 260 | 280 |
| Detection Methods | ▪Cross-beam(PAS-M) : Transmissive 3-point cross-beam detection method |
| Sensing distance | ▪Cross-beam : 0.5 ~ 5 m ▪Parallel-beam : 0.1 ~ 5 m |
| Sensing object | ▪Cross-beam : Opaque object over Ø20 mm (Center 75% of the area between the transmitter and receiver) |
| Optical axis pitch | 20 mm |
| Light source | IR (850nm) |
| Power voltage | 12 - 24 V d.c. ±10% Ripple(p-p) 10% Max |
| Control output | ▪NPN / PNP open collector output ▪Load Current: Max. 100mA (26.4 V d.c. standard) ▪Residual voltage - NPN : Max. 1 V, PNP : Max. 2 V |
| Operation mode | Light On or Dark On |
| Operation LED | ▪Transmitter : Power indicator(Green LED), M/S display(Red LED) ▪Receiver : Light on stability display(Green LED), Output Display(Red LED), E1 display(Red LED), Power indicator (Blue LED) |
| Protection circuit | Power reverse connection protection, Output short-circuit over-current protection, Mutual interference prevation function |
| Response Time | ▪Cross-beam : 15 ms or less when light blocked, 30 ms or less when light received ▪Parallel-beam : both 10 ms or less when light blocked/received |
| Insulation resistance | Min. 20 MΩ (500 V d.c. mega standard) |
| Noise immunity | Square wave noise by noise simulator (pulse width 1 µs) ± 240 V d.c. |
| Dielectric strength | 1,000 V a.c. (50/60 ㎐ 1min) |
| Vibration resistance | 10 ~ 55 Hz, sweep : 1.5 mm, X·Y·Z in each direction for 2 hours |
| Shock resistance | 500 m/s², X·Y·Z each direction 3 times |
| Ambient illumination | Sunlight : Max. 11,000 Lux, Incandescent lamp : Max. 3,000 Lux (Receiver illumination) |
| Ambient temperature | During operation : -10 ~ +55 ℃, During storage : -25 ~ +70 ℃ (Without condensation or icing) |
| Ambient humidity | 35 ~ 85 % RH (Without condensation) |
| Degree of protection | IP40 |
| Connection method | cable withdrawal type (Number of wires : 5P, Code length : 3m , Dimension : Ø4mm) |
| Mate rial | Case | ABS |
| Front Cover | PMMA |
| Lens | PMMA |
| No | Type | Category | Title | File |
| 1 | Manual > Instruction Manual | Area Sensor | PAS series Instruction Manual |
| No | Mark | Category | Title | File |
| 1 | Certification > CE | Area Sensor | PAS / PAN series (EMC) |
| 2 | Certification > CE | Area Sensor | PAS-M/T12 EMC (AoC) |
| 3 | Certification > CE | Area Sensor | PAS-M/T16 EMC (AoC) |
| 4 | Certification > CE | Area Sensor | PAS-M/T20 EMC (AoC) |
| 5 | Certification > CE | Area Sensor | PAS-M/T24 EMC (AoC) |
| 6 | Certification > CE | Area Sensor | PAS-M/T28 EMC (AoC) |
| 7 | Certification > CE | Area Sensor | PAS-M/T4 EMC (AoC) |
| 8 | Certification > CE | Area Sensor | PAS-M/T8 EMC (AoC) |
| ▪Load Current | Max. 100mA (26.4 V d.c. standard) ▪Residual voltage - NPN : Max. 1 V, PNP : Max. 2 V |
| 10 ~ 55 Hz, sweep | 1.5 mm, X·Y·Z in each direction for 2 hours |
| During operation | -10 ~ +55 ℃, During storage : -25 ~ +70 ℃ (Without condensation or icing) |
| cable withdrawal type (Number of wires | 5P, Code length : 3m , Dimension : Ø4mm) |