LT series

HANYOUNG NUX Electricals Sign Tower / Signal Lights

LT series

LT series is a Hanyoung NUX counter / timer for counting and timing operations. Key specifications include Operating time range: 0.01 sec ~ 9999 hour; Input method: - | Non-voltage input, impedance at short circuit: max. 1 kΩ Residual voltage at short circuit:max. 0.5V Impedance at open: min. 100 kΩ..
  • Brand HANYOUNG NUX
  • Category Electricals
  • Subcategory Sign Tower / Signal Lights
Interested in this product? LT series
Product insights

Everything you need to evaluate this product

Explore performance details, construction highlights, applications, and technical information in one clear overview.

Quality assured Technical details Industrial use Expert support

Product Overview

LT series is a Hanyoung NUX counter / timer for counting events and controlling time-based operations. Its model configuration determines the input method, timing or counting range, display and output functions, with model information of LT4 | LT4S. Operating time range: 0.01 sec ~ 9999 hour; Display: Wide viewing angle negative LCD display; Display mode: Addition and subtraction; Display digits: 4 digits.

The operating range, signal conditions, display format, computation speed and connection method should be checked against the machine sequence before installation. Character height: PV display : 14 mm, SV display : 8.5 mm; PV display: 14 mm, SV display : 8.5 mm; External connection: Socket 8 pin; Insulation resistance: 100 MΩ min (500 V d.c. Megger standard, conductive part terminal and exposed unfilled metal).

Key Features

Key strengths of the LT series come from the combination of its functional configuration and practical installation specifications. The following characteristics highlight the values that matter most when comparing the product with equipment requirements.

Operating time range: 0.01 sec ~ 9999 hour; Input method: - | Non-voltage input, impedance at short circuit: max. 1 kΩ Residual voltage at short circuit:max. 0.5V Impedance at open: min. 100 kΩ.; Power voltage: 24 - 240 V a.c. 50/60 Hz or 24 - 240 V d.c. (dual usage); Display: Wide viewing angle negative LCD display; External connection: Socket 8 pin.

  • Operating time range: 0.01 sec ~ 9999 hour
  • Input method: - | Non-voltage input, impedance at short circuit: max. 1 kΩ Residual voltage at short circuit:max. 0.5V Impedance at open: min. 100 kΩ.
  • Power voltage: 24 - 240 V a.c. 50/60 Hz or 24 - 240 V d.c. (dual usage)
  • Display: Wide viewing angle negative LCD display
  • External connection: Socket 8 pin
  • Display mode: Addition and subtraction
  • Display digits: 4 digits
  • Character height: PV display : 14 mm, SV display : 8.5 mm
  • PV display: 14 mm, SV display : 8.5 mm
  • Voltage fluctuation rate: ± 10 % of power voltage

Technical Characteristics

The LT series technical characteristics define the supported input conditions, counting or timing range, display resolution, computation speed and output behaviour. These values determine how the unit responds to machine signals. Power voltage: 24 - 240 V a.c. 50/60 Hz or 24 - 240 V d.c. (dual usage); Voltage fluctuation rate: ± 10 % of power voltage; Power consumption: Max. 4 VA (24 - 240 V a.c. 50/60 Hz) Max. 1.6 W (24 - 240 V d.c.) | Max. 4.5 VA (24 - 240 V a.c. 50/60 Hz) Max. 2 W (24 - 240 V d.c.); Contact capacity: 250 V a.c. 5A resistive load | 250 V a.c. 3A resistive load (N.O.:5A, N.C.:3A).

Additional technical characteristics include .

Design and Construction

The physical design of LT series should be considered together with the installation environment and the available mounting or display arrangement. Dielectric strength: 2000 V a.c. 60 Hz for 1 minute (conductive part terminal and exposed unfilled metal); Noise immunity: ± 2 kV (among operation power terminals, pulse width = 1 us, square-wave noise by noise simulator); Vibration resistance: 10 - 55 Hz (for 1 minute) single amplitude 0.5 mm X, Y, Z each direction, 2 h; Shock resistance: 300 m/s² (30G) X, Y, Z each direction, 3 times.

Further construction and environmental details include Ambient temperature: -10 ~ 55 ℃ (without condensation); Storage temperature: -25 ~ 65 ℃ (without condensation); Ambient humidity: 35 ~ 85 % RH.

Integration and Operation

Integration of LT series begins with matching its connection, input or control signal and output requirements to the surrounding equipment. Operating time range: 0.01 sec ~ 9999 hour; Input method: - | Non-voltage input, impedance at short circuit: max. 1 kΩ Residual voltage at short circuit:max. 0.5V Impedance at open: min. 100 kΩ.; Power voltage: 24 - 240 V a.c. 50/60 Hz or 24 - 240 V d.c. (dual usage); Display: Wide viewing angle negative LCD display.

Additional operating and interface details include External connection: Socket 8 pin; Display mode: Addition and subtraction; Display digits: 4 digits. These values provide a practical reference for wiring, setup and normal operation within the selected configuration.

Selection and Use

Choose LT series by confirming the exact model or configuration against the required operating conditions. The available model information is LT4 | LT4S. Model: LT4 | LT4S; Degree of protection: IP66 (front panel); Operating time range: 0.01 sec ~ 9999 hour; Input method: - | Non-voltage input, impedance at short circuit: max. 1 kΩ Residual voltage at short circuit:max. 0.5V Impedance at open: min. 100 kΩ..

Before installation, confirm Power voltage: 24 - 240 V a.c. 50/60 Hz or 24 - 240 V d.c. (dual usage); Display: Wide viewing angle negative LCD display; External connection: Socket 8 pin. Matching the model, electrical ratings, signal requirements, physical arrangement and environmental limits helps keep the product within its specified operating conditions.

SpecificationDetails
ModelLT4 | LT4S
Power voltage24 - 240 V a.c. 50/60 Hz or 24 - 240 V d.c. (dual usage)
Voltage fluctuation rate± 10 % of power voltage
Power consumptionMax. 4 VA (24 - 240 V a.c. 50/60 Hz) Max. 1.6 W (24 - 240 V d.c.) | Max. 4.5 VA (24 - 240 V a.c. 50/60 Hz) Max. 2 W (24 - 240 V d.c.)
DisplayWide viewing angle negative LCD display
Display modeAddition and subtraction
Display digits4 digits
Character heightPV display : 14 mm, SV display : 8.5 mm
Return timeMax. 100 ms
External connectionSocket 8 pin
Operating time range0.01 sec ~ 9999 hour
Exter nal inputInput signal | Power on start | START, INHIBIT, RESET
Input method- | Non-voltage input, impedance at short circuit: max. 1 kΩ Residual voltage at short circuit:max. 0.5V Impedance at open: min. 100 kΩ.
Minimum input time- | START, INHIBIT, RESET min. input signal width 1ms / 20ms selection
Operating time errorPower START : max. ± 0.01 % ±0.05 sec., Signal START : max. ± 0.005 % ±0.03 sec.
Con trol out putOpera tion mode | POND / PFKF / PFKN / PINT / TWON / TWOF / S-D | SOND / SFKF / SINT / SNFN / SNFF / SOFD / S.OND / S.FKN / S.INT / S.ODR
Contact compo sitionTime limit 2c, Instantaneous 1c + Time limit 1c | Time limit 1c
Contact capacity250 V a.c. 5A resistive load | 250 V a.c. 3A resistive load (N.O.:5A, N.C.:3A)
Relay lifeMechanical life: min. 10,000,000 times, Electrical life: min. 100,000 times (250 V a.c. 5A resistive load)
Insulation resistance100 MΩ min (500 V d.c. Megger standard, conductive part terminal and exposed unfilled metal)
Dielectric strength2000 V a.c. 60 Hz for 1 minute (conductive part terminal and exposed unfilled metal)
Noise immunity± 2 kV (among operation power terminals, pulse width = 1 us, square-wave noise by noise simulator)
Vibration resistance10 - 55 Hz (for 1 minute) single amplitude 0.5 mm X, Y, Z each direction, 2 h
Shock resistance300 m/s² (30G) X, Y, Z each direction, 3 times
Ambient temperature-10 ~ 55 ℃ (without condensation)
Storage temperature-25 ~ 65 ℃ (without condensation)
Ambient humidity35 ~ 85 % RH
Degree of protectionIP66 (front panel)
NoType | Category | Title | File
1Manual > Instruction Manual | Counter / Timer | LT series Instruction manual
1CAD > 2D | Counter / Timer | LT series (2D)
2CAD > 3D | Counter / Timer | LT series (3D)
NoMark | Category | Title | File
1Certification > CE | Counter / Timer | LT4 (EMC)
2Certification > CE | Counter / Timer | LT4 (LVD)
3Certification > KC | Counter / Timer | LT4
PV display14 mm, SV display : 8.5 mm
Non-voltage input, impedance at short circuitmax. 1 kΩ
Residual voltage at short circuitmax. 0.5V
Power STARTmax. ± 0.01 % ±0.05 sec., Signal START : max. ± 0.005 % ±0.03 sec.
250 V a.c. 3A resistive load (N.O.5A, N.C.:3A)
Shop by category
Category

Browse product families and jump into the exact catalog section you need.

Product categories