HPA-12

HANYOUNG NUX Electricals Encoder

HPA-12

HPA-12 is a Hanyoung NUX sensor controller for sensor signal monitoring and control. Key specifications include Power for Sensor: 12 V d.c. (±10 %) below 50 mA; Connectable Sensor (Input): Transistor output sensor of NPN, PNP.
  • Brand HANYOUNG NUX
  • Category Electricals
  • Subcategory Encoder
Interested in this product? HPA-12
Product insights

Everything you need to evaluate this product

Explore performance details, construction highlights, applications, and technical information in one clear overview.

Quality assured Technical details Industrial use Expert support

Product Overview

HPA-12 is a Hanyoung NUX sensor controller for processing sensor signals and providing control outputs. Its model configuration includes HPA-12. Control Output: Relay Contact : 1c (250 V a.c. 3 A Resistive Load) (Rated Load Lifetime : above 100 thousands times); Response Time: Approx. 10 ㎳; Rated Voltage: 220 V a.c. (voltage fluctuation rate ±10 %) 50/60 Hz; Power Consumption: Approx. 4 VA.

Input levels, sensor supply, output type, response speed and operating functions determine how the controller fits into the control circuit. Weight: Approx. 260 g; Power cable: 1,500 VP, Pulse width : 0.5 μs (by a noise simulator); Operating Ambient Temperature/ Humidity: -10 ~ 50 ℃, 35 ~ 85 % R.H. (with no freezing or no condensation); Noise Immunity: Power cable : 1,500 VP, Pulse width : 0.5 μs (by a noise simulator).

Key Features

Key strengths of the HPA-12 come from the combination of its functional configuration and practical installation specifications. The following characteristics highlight the values that matter most when comparing the product with equipment requirements.

Power for Sensor: 12 V d.c. (±10 %) below 50 mA; Connectable Sensor (Input): Transistor output sensor of NPN, PNP; Control Output: Relay Contact : 1c (250 V a.c. 3 A Resistive Load) (Rated Load Lifetime : above 100 thousands times); Noise Immunity: Power cable : 1,500 VP, Pulse width : 0.5 μs (by a noise simulator); Response Time: Approx. 10 ㎳.

  • Power for Sensor: 12 V d.c. (±10 %) below 50 mA
  • Connectable Sensor (Input): Transistor output sensor of NPN, PNP
  • Control Output: Relay Contact : 1c (250 V a.c. 3 A Resistive Load) (Rated Load Lifetime : above 100 thousands times)
  • Noise Immunity: Power cable : 1,500 VP, Pulse width : 0.5 μs (by a noise simulator)
  • Response Time: Approx. 10 ㎳
  • Rated Voltage: 220 V a.c. (voltage fluctuation rate ±10 %) 50/60 Hz
  • Power Consumption: Approx. 4 VA
  • Operating Ambient Temperature/ Humidity: -10 ~ 50 ℃, 35 ~ 85 % R.H. (with no freezing or no condensation)
  • Dielectric Strength: 1,500 V a.c. for 1 minute (between the power and the output)
  • Insulated Resistance: 20 MΩ (500 V d.c. at mega between the power and the output)

Technical Characteristics

The main technical characteristics of HPA-12 are defined by its electrical ratings, operating inputs or outputs, performance values and control or indication functions. These specifications provide the working limits for the selected configuration. Dielectric Strength: 1,500 V a.c. for 1 minute (between the power and the output); Insulated Resistance: 20 MΩ (500 V d.c. at mega between the power and the output); Vibration resistance: 10 - 55 Hz (cycle for 1 minute), double amplitudes width : 1.5 ㎜, each X·Y·Z direction for 2 hours (but while the power is off); Shock Resistance: 100 m/s² (approx. 10 G), each X·Y·Z direction for 2 times (but while the power is off).

Additional technical characteristics include .

Design and Construction

The physical design of HPA-12 should be considered together with the installation environment and the available mounting or display arrangement. Power for Sensor: 12 V d.c. (±10 %) below 50 mA; Connectable Sensor (Input): Transistor output sensor of NPN, PNP; Control Output: Relay Contact : 1c (250 V a.c. 3 A Resistive Load) (Rated Load Lifetime : above 100 thousands times); Noise Immunity: Power cable : 1,500 VP, Pulse width : 0.5 μs (by a noise simulator).

Further construction and environmental details include Response Time: Approx. 10 ㎳; Rated Voltage: 220 V a.c. (voltage fluctuation rate ±10 %) 50/60 Hz; Power Consumption: Approx. 4 VA.

Integration and Operation

Integration of HPA-12 begins with matching its connection, input or control signal and output requirements to the surrounding equipment. Power for Sensor: 12 V d.c. (±10 %) below 50 mA; Connectable Sensor (Input): Transistor output sensor of NPN, PNP; Control Output: Relay Contact : 1c (250 V a.c. 3 A Resistive Load) (Rated Load Lifetime : above 100 thousands times); Noise Immunity: Power cable : 1,500 VP, Pulse width : 0.5 μs (by a noise simulator).

Additional operating and interface details include Response Time: Approx. 10 ㎳; Rated Voltage: 220 V a.c. (voltage fluctuation rate ±10 %) 50/60 Hz; Power Consumption: Approx. 4 VA. These values provide a practical reference for wiring, setup and normal operation within the selected configuration.

Selection and Use

Choose HPA-12 by confirming the exact model or configuration against the required operating conditions. The available model information is HPA-12. Model: HPA-12; Power for Sensor: 12 V d.c. (±10 %) below 50 mA; Connectable Sensor (Input): Transistor output sensor of NPN, PNP; Control Output: Relay Contact : 1c (250 V a.c. 3 A Resistive Load) (Rated Load Lifetime : above 100 thousands times).

Before installation, confirm Noise Immunity: Power cable : 1,500 VP, Pulse width : 0.5 μs (by a noise simulator); Response Time: Approx. 10 ㎳; Rated Voltage: 220 V a.c. (voltage fluctuation rate ±10 %) 50/60 Hz. Matching the model, electrical ratings, signal requirements, physical arrangement and environmental limits helps keep the product within its specified operating conditions.

SpecificationDetails
ModelHPA-12
Rated Voltage220 V a.c. (voltage fluctuation rate ±10 %) 50/60 Hz
Power ConsumptionApprox. 4 VA
Power for Sensor12 V d.c. (±10 %) below 50 mA
Connectable Sensor (Input)Transistor output sensor of NPN, PNP
Control OutputRelay Contact : 1c (250 V a.c. 3 A Resistive Load) (Rated Load Lifetime : above 100 thousands times)
Response TimeApprox. 10 ㎳
Operating Ambient Temperature/ Humidity-10 ~ 50 ℃, 35 ~ 85 % R.H. (with no freezing or no condensation)
Noise ImmunityPower cable : 1,500 VP, Pulse width : 0.5 μs (by a noise simulator)
Dielectric Strength1,500 V a.c. for 1 minute (between the power and the output)
Insulated Resistance20 MΩ (500 V d.c. at mega between the power and the output)
Vibration resistance10 - 55 Hz (cycle for 1 minute), double amplitudes width : 1.5 ㎜, each X·Y·Z direction for 2 hours (but while the power is off)
Shock Resistance100 m/s² (approx. 10 G), each X·Y·Z direction for 2 times (but while the power is off)
WeightApprox. 260 g
NoType | Category | Title | File
1Manual > Instruction Manual | Sensor Controller | HPA-12 Instruction Manual
2Manual > Catalogue | Sensor Controller | HPA-12 Catalogue
Relay Contact1c
(Rated Load Lifetimeabove 100 thousands times)
Power cable1,500 VP, Pulse width : 0.5 μs (by a noise simulator)
10 - 55 Hz (cycle for 1 minute), double amplitudes width1.5 ㎜, each X·Y·Z direction for 2 hours (but while the power is off)