HLP1 Non-Power Scale Meters is a Hanyoung NUX panel meter designed for industrial measurement, indication and process monitoring. Its configuration is determined by the available input signals, measurement or recording functions, display and output characteristics, with model information of HLP1. Input signal: 4 - 20 mA d.c.; Sampling time: Selection done by the parameter (0.5, 1, 2, 3, 4, 5 sec); Indication accuracy: ±0.3 % of FS ±1 Digit; Displaying characters: 7 segments LED (Red).
The listed measurement range, accuracy, input method, display format and connection details provide the main selection points for panel and control-system integration. Displayable digit: 4 digits (-1999 ~ 9999); Setting method: Operation system about front side of switch; Vibration: Malfunction | 10 - 55 ㎐ single amplitude X · Y · Z each direction 10 minutes; Shock: Malfunction | 100 m/s², 3 times each in X · Y · Z 6 direction.
Key strengths of the HLP1 Non-Power Scale Meters come from the combination of its functional configuration and practical installation specifications. The following characteristics highlight the values that matter most when comparing the product with equipment requirements.
Displaying characters: 7 segments LED (Red); Input signal: 4 - 20 mA d.c.; Power supply voltage: Non-voltage type; Indication accuracy: ±0.3 % of FS ±1 Digit; Ambient temperature & humidity: -5 ~ 50 ℃, 20 ~ 90 % R.H..
The main technical characteristics of HLP1 Non-Power Scale Meters are defined by its electrical ratings, operating inputs or outputs, performance values and control or indication functions. These specifications provide the working limits for the selected configuration. Power supply voltage: Non-voltage type; Displaying characters: 7 segments LED (Red); Input signal: 4 - 20 mA d.c.; Indication accuracy: ±0.3 % of FS ±1 Digit.
Additional technical characteristics include Ambient temperature & humidity: -5 ~ 50 ℃, 20 ~ 90 % R.H.; Sampling time: Selection done by the parameter (0.5, 1, 2, 3, 4, 5 sec); Displayable digit: 4 digits (-1999 ~ 9999).
The physical design of HLP1 Non-Power Scale Meters should be considered together with the installation environment and the available mounting or display arrangement. Ambient temperature & humidity: -5 ~ 50 ℃, 20 ~ 90 % R.H.; Storage temperature: -25 ~ 70 ℃ (however, there should be no condensation); Displaying characters: 7 segments LED (Red); Input signal: 4 - 20 mA d.c..
Further construction and environmental details include Power supply voltage: Non-voltage type; Indication accuracy: ±0.3 % of FS ±1 Digit; Sampling time: Selection done by the parameter (0.5, 1, 2, 3, 4, 5 sec).
Integration of HLP1 Non-Power Scale Meters begins with matching its connection, input or control signal and output requirements to the surrounding equipment. Displaying characters: 7 segments LED (Red); Input signal: 4 - 20 mA d.c.; Power supply voltage: Non-voltage type; Indication accuracy: ±0.3 % of FS ±1 Digit.
Additional operating and interface details include Ambient temperature & humidity: -5 ~ 50 ℃, 20 ~ 90 % R.H.; Sampling time: Selection done by the parameter (0.5, 1, 2, 3, 4, 5 sec); Displayable digit: 4 digits (-1999 ~ 9999). These values provide a practical reference for wiring, setup and normal operation within the selected configuration.
Choose HLP1 Non-Power Scale Meters by confirming the exact model or configuration against the required operating conditions. The available model information is HLP1. Model: HLP1; Displaying characters: 7 segments LED (Red); Input signal: 4 - 20 mA d.c.; Power supply voltage: Non-voltage type.
Before installation, confirm Indication accuracy: ±0.3 % of FS ±1 Digit; Ambient temperature & humidity: -5 ~ 50 ℃, 20 ~ 90 % R.H.; Sampling time: Selection done by the parameter (0.5, 1, 2, 3, 4, 5 sec). Matching the model, electrical ratings, signal requirements, physical arrangement and environmental limits helps keep the product within its specified operating conditions.
| Specification | Details |
|---|---|
| Model | HLP1 |
| Power supply voltage | Non-voltage type |
| Input signal | 4 - 20 mA d.c. |
| Indication accuracy | ±0.3 % of FS ±1 Digit |
| Sampling time | Selection done by the parameter (0.5, 1, 2, 3, 4, 5 sec) |
| Displaying characters | 7 segments LED (Red) |
| Displayable digit | 4 digits (-1999 ~ 9999) |
| Decimal point setting | User random selection |
| Setting method | Operation system about front side of switch |
| Vibration | Malfunction | 10 - 55 ㎐ single amplitude X · Y · Z each direction 10 minutes |
| Durability | 10 - 55 ㎐ single amplitude X · Y · Z each direction 2 hours |
| Shock | Malfunction | 100 m/s², 3 times each in X · Y · Z 6 direction |
| Durability | 300 m/s², 3 times each in X · Y · Z 6 direction |
| Ambient temperature & humidity | -5 ~ 50 ℃, 20 ~ 90 % R.H. |
| Storage temperature | -25 ~ 70 ℃ (however, there should be no condensation) |