Explore performance details, construction highlights, applications, and technical information in one clear overview.
BA1 is a Hanyoung NUX panel meter designed for industrial measurement, indication and process monitoring. Its configuration is determined by the available input signals, measurement or recording functions, display and output characteristics, with model information of Code | Description. Input signal: Voltage, current, current loop (4 - 20 ㎃ d.c., 1 - 5 V d.c.); Sampling cycle: 300 ㎳; Max displayable digit: ± 1999; Displaying part: 7 segments LED.
The listed measurement range, accuracy, input method, display format and connection details provide the main selection points for panel and control-system integration. Decimal point indication: 10¹, 10² and 10³ indication by the backside terminal connection; Polarity indication: Display “-” automatically when input signal is opposite.; Indication when range is exceeded: Indicate with 1□□□; Indication when range is short: Indicate with -1□□□.
Key strengths of the BA1 come from the combination of its functional configuration and practical installation specifications. The following characteristics highlight the values that matter most when comparing the product with equipment requirements.
Max displayable digit: ± 1999; Input signal: Voltage, current, current loop (4 - 20 ㎃ d.c., 1 - 5 V d.c.); Power supply voltage: 5 V d.c. | 12 - 24 V d.c.; Ambient temperature: 0 ~ 50 ℃; Sampling cycle: 300 ㎳.
The main technical characteristics of BA1 are defined by its electrical ratings, operating inputs or outputs, performance values and control or indication functions. These specifications provide the working limits for the selected configuration. Power supply voltage: 5 V d.c. | 12 - 24 V d.c.; Power consumption: Approx. 3 W | Approx. 5 W; Power supply voltage: - | No indication : 5 V d.c.; Max displayable digit: ± 1999.
Additional technical characteristics include Input signal: Voltage, current, current loop (4 - 20 ㎃ d.c., 1 - 5 V d.c.); Ambient temperature: 0 ~ 50 ℃; Sampling cycle: 300 ㎳.
The physical design of BA1 should be considered together with the installation environment and the available mounting or display arrangement. Insulation resistance: 10 ㏁ min ( 500 V d.c.); Noise resistance: Power supply terminal normal mode ± 200 V Power supply terminal common mode ± 500 V; Vibration durability: 10 - 55 ㎐ Peak amplitude for 2 hours each in X, Y, Z directions; Shock durability: 300 m/s² (Approx. 30 G).
Further construction and environmental details include Ambient temperature: 0 ~ 50 ℃; Ambient humidity: 35 ~ 85 % RH; Storage temperature: -10 ~ 70 ℃.
Integration of BA1 begins with matching its connection, input or control signal and output requirements to the surrounding equipment. Response speed: Approx. 2 sec (max range); Output: N | instruction only; Max displayable digit: ± 1999; Input signal: Voltage, current, current loop (4 - 20 ㎃ d.c., 1 - 5 V d.c.).
Additional operating and interface details include Power supply voltage: 5 V d.c. | 12 - 24 V d.c.; Ambient temperature: 0 ~ 50 ℃; Sampling cycle: 300 ㎳. These values provide a practical reference for wiring, setup and normal operation within the selected configuration.
Choose BA1 by confirming the exact model or configuration against the required operating conditions. The available model information is Code | Description. Model: Code | Description; Max displayable digit: ± 1999; Input signal: Voltage, current, current loop (4 - 20 ㎃ d.c., 1 - 5 V d.c.); Power supply voltage: 5 V d.c. | 12 - 24 V d.c..
Before installation, confirm Ambient temperature: 0 ~ 50 ℃; Sampling cycle: 300 ㎳; Displaying part: 7 segments LED. Matching the model, electrical ratings, signal requirements, physical arrangement and environmental limits helps keep the product within its specified operating conditions.
| Specification | Details |
|---|---|
| Power supply voltage | 5 V d.c. | 12 - 24 V d.c. |
| Power consumption | Approx. 3 W | Approx. 5 W |
| Insulation resistance | 10 ㏁ min ( 500 V d.c.) |
| Dielectric strenght | 1,500 V a.c. for 1 min (power terminal - input terminal) |
| Noise resistance | Power supply terminal normal mode ± 200 V Power supply terminal common mode ± 500 V |
| Vibration durability | 10 - 55 ㎐ Peak amplitude for 2 hours each in X, Y, Z directions |
| Shock durability | 300 m/s² (Approx. 30 G) |
| Ambient temperature | 0 ~ 50 ℃ |
| Ambient humidity | 35 ~ 85 % RH |
| Storage temperature | -10 ~ 70 ℃ |
| Input signal | Voltage, current, current loop (4 - 20 ㎃ d.c., 1 - 5 V d.c.) |
| A/D conversion type | Duplex integral type |
| Sampling cycle | 300 ㎳ |
| Response speed | Approx. 2 sec (max range) |
| Max displayable digit | ± 1999 |
| Displaying part | 7 segments LED |
| Decimal point indication | 10¹, 10² and 10³ indication by the backside terminal connection |
| Polarity indication | Display “-” automatically when input signal is opposite. |
| Indication when range is exceeded | Indicate with 1□□□ |
| Indication when range is short | Indicate with -1□□□ |
| Model | Code | Description |
| BA1- | - | - | Mini DC indicator 48(W) x 24(H) ㎜ |
| Output | N | instruction only |
| Input | D | 10 | DC voltage (voltmeter) |
| 20 | DC current (ammeter) |
| 11 | DC voltmeter (1 - 5 V DC) |
| 21 | DC ammeter (4 - 20 ㎃ DC) |
| Range code | 1~8 | Refer to the measurement range code |
| Power supply voltage | - | No indication : 5 V d.c. |
| A | 12 - 24 V d.c. |