TPR-3P is a Hanyoung NUX thyristor power regulator for controlled power regulation of resistive loads. The configuration covers multiple current and voltage options, with model information of TPR-3. Power supply voltage: 220 V a.c, 380 V a.c., 440 V a.c.; Applying frequency: 50 ㎐/60 ㎐(Dual usage); Rated current: 200 A | 250 A | 320 A | 500 A; Output voltage: More than 95 % of the input voltage (with the max current input).
The selected rating should be matched to the load, control input, regulation method, cooling arrangement and operating environment of the installation. Display method: Output displayed by the LED; Weight: 200/250 A : approx. 15 ㎏ 320 A : approx. 22 ㎏ 500 A : approx. 35 ㎏; Protective circuit: Short detection by fuse, Overcurrent detection alarm, Heatsink overheat alarm; Insulation resistance: minimum 100 ㏁ (500 V d.c. mega standard).
Key strengths of the TPR-3P come from the combination of its functional configuration and practical installation specifications. The following characteristics highlight the values that matter most when comparing the product with equipment requirements.
Rated current: 200 A | 250 A | 320 A | 500 A; Output voltage: More than 95 % of the input voltage (with the max current input); Applying load: Resistive load; Power supply voltage: 220 V a.c, 380 V a.c., 440 V a.c.; Applying frequency: 50 ㎐/60 ㎐(Dual usage).
The TPR-3P technical profile covers load rating, current input, power-control method, output voltage and cooling requirements. Together these parameters define the regulator configuration for resistive-load control. Output adjustable range: 0 ~ 100 %; Dielectric strength: For 1 minute at 2000 V a.c. 50/60 Hz; Ambient temperatureㆍ humidity: 0 ~ 40 ℃, 35 ~ 85 % RH (but no icing allowed); Storage temperature: -25 ~ 70 ℃.
Additional technical characteristics include .
The physical design of TPR-3P should be considered together with the installation environment and the available mounting or display arrangement. Rated current: 200 A | 250 A | 320 A | 500 A; Output voltage: More than 95 % of the input voltage (with the max current input); Applying load: Resistive load; Power supply voltage: 220 V a.c, 380 V a.c., 440 V a.c..
Further construction and environmental details include Applying frequency: 50 ㎐/60 ㎐(Dual usage); Output adjustable range: 0 ~ 100 %; Protective circuit: Short detection by fuse, Overcurrent detection alarm, Heatsink overheat alarm.
Integration of TPR-3P begins with matching the current input, control method, load voltage and cooling arrangement to the power circuit. Rated current: 200 A | 250 A | 320 A | 500 A; Output voltage: More than 95 % of the input voltage (with the max current input); Applying load: Resistive load; Power supply voltage: 220 V a.c, 380 V a.c., 440 V a.c..
Additional operating and interface details include Applying frequency: 50 ㎐/60 ㎐(Dual usage); Output adjustable range: 0 ~ 100 %; Protective circuit: Short detection by fuse, Overcurrent detection alarm, Heatsink overheat alarm. These values provide a practical reference for wiring, setup and normal operation within the selected configuration.
Choose TPR-3P by confirming the exact model or configuration against the required operating conditions. The available model information is TPR-3. Model: TPR-3; Rated current: 200 A | 250 A | 320 A | 500 A; Output voltage: More than 95 % of the input voltage (with the max current input); Applying load: Resistive load.
Before installation, confirm Power supply voltage: 220 V a.c, 380 V a.c., 440 V a.c.; Applying frequency: 50 ㎐/60 ㎐(Dual usage); Output adjustable range: 0 ~ 100 %. Matching the model, electrical ratings, signal requirements, physical arrangement and environmental limits helps keep the product within its specified operating conditions.
| Specification | Details |
|---|---|
| Model | TPR-3 |
| Power supply voltage | 220 V a.c, 380 V a.c., 440 V a.c. |
| Applying frequency | 50 ㎐/60 ㎐(Dual usage) |
| Rated current | 200 A | 250 A | 320 A | 500 A |
| Protective circuit | Short detection by fuse, Overcurrent detection alarm, Heatsink overheat alarm |
| Applying load | Resistive load |
| Control input | Current Input | 4 - 20 ㎃ d.c. |
| Voltage Input | 0 - 5 V d.c., 1 - 5 V d.c., 0 - 10 V d.c., |
| Contact Input | ON/OFF |
| External V.R | External volume (10 KΩ) |
| Control type | Phase control, ON/OFF control, Fixed cycle control |
| Start type | SOFT START / DOWN |
| Output voltage | More than 95 % of the input voltage (with the max current input) |
| Cooling type | Forced cooling Separate power supply for fan operation |
| Display method | Output displayed by the LED |
| Insulation resistance | minimum 100 ㏁ (500 V d.c. mega standard) |
| Output adjustable range | 0 ~ 100 % |
| Dielectric strength | For 1 minute at 2000 V a.c. 50/60 Hz |
| Line noise | Noise (2 ㎸) by the noise simulator |
| Ambient temperatureㆍ humidity | 0 ~ 40 ℃, 35 ~ 85 % RH (but no icing allowed) |
| Storage temperature | -25 ~ 70 ℃ |
| Weight | 200/250 A : approx. 15 ㎏ 320 A : approx. 22 ㎏ 500 A : approx. 35 ㎏ |
| No | Type | Category | Title | File |
| 1 | Manual > Instruction Manual | Thyristor Power Regulator | TPR-3P Instruction Manual |
| 2 | Manual > Instruction Manual | Thyristor Power Regulator | TPR-3P Instruction Manual(old) |
| 3 | Manual > Catalogue | Thyristor Power Regulator | TPR-3P Catalogue |
| 1 | CAD > 2D | Thyristor Power Regulator | TPR-3P (150,200,250A)_2D |
| 2 | CAD > 2D | Thyristor Power Regulator | TPR-3P (320A)_2D |
| 3 | CAD > 2D | Thyristor Power Regulator | TPR-3P (500A)_2D |
| 4 | CAD > 2D | Thyristor Power Regulator | TPR-3P (70,100A )_2D |
| 5 | CAD > 2D | Thyristor Power Regulator | TPR-3P_ASSY (2D) |
| 6 | CAD > 3D | Thyristor Power Regulator | TPR-3P (3D) |
| 200/250 A | approx. 15 ㎏ |
| 320 A | approx. 22 ㎏ |
| 500 A | approx. 35 ㎏ |