Explore performance details, construction highlights, applications, and technical information in one clear overview.
The APEM Panel Switches 1213C3 are robust, high-reliability autoswitches designed for industrial applications. Featuring a 1,000 MΩ min. insulation resistance at 500 VDC and 2,000 Vrms dielectric strength, these switches ensure safe operation in demanding environments. With an electrical life of 10,000 cycles and a temperature range of -20 °C to +55 °C, they deliver precise control for critical systems.
The APEM Panel Switches 1213C3 are precision-engineered autoswitches designed for reliable operation in industrial control panels. These switches combine high electrical safety standards with durable construction to meet stringent requirements in automation and machinery applications. With a minimum insulation resistance of 1,000 MΩ at 500 VDC and dielectric strength exceeding 2,000 Vrms (50 Hz), the 1213C3 ensures robust performance under electrical stress. The switch supports 10,000 cycles of operation at full load and operates within a wide temperature range of -20 °C to +55 °C, making it suitable for both harsh and controlled environments. Its simple NO (Normally Open) electrical function and quick-connect solder lug terminals provide straightforward integration into industrial control systems.
The APEM Panel Switches 1213C3 deliver precise electrical performance with a minimum insulation resistance of 1,000 MΩ at 500 VDC and dielectric strength exceeding 2,000 Vrms (50 Hz) between terminals. This ensures reliable operation in high-voltage environments while maintaining safety standards. The switch supports 10,000 cycles of electrical operation at full load, providing long-term durability for critical industrial applications.
Engineered for versatility, the 1213C3 operates within a wide temperature range of -20 °C to +55 °C, accommodating extreme conditions. Its robust construction ensures consistent performance in both cold and hot environments, making it ideal for outdoor installations or industrial settings with fluctuating temperatures.
The switch features solder lug quick connect terminals that simplify installation and reduce assembly time. With a maximum torque of 1.50 Nm (1.10 ft.lb) for nut tightening, the 1213C3 ensures secure connections without damage. The panel thickness is limited to 5 mm (.196) max., allowing for integration into standard control panels.
The 1213C3 supports a maximum current of 4 A at 250 VAC or 8 A at 125 VAC for resistive loads, with precise contact resistance of 10 mΩ. Its NO (Normally Open) function ensures safe operation by maintaining an open circuit until activated, reducing the risk of unintended electrical paths.
| Feature | Specification |
|---|---|
| Insulation resistance | 1,000 MΩ min. at 500 VDC |
| Dielectric strength | 2,000 Vrms 50 Hz min. between terminals3,000 Vrms 50 Hz min. between terminals and frame |
| Torque | 1.50 Nm (1.10 Ft.lb) max. applied to nut |
| Panel thickness | 5 mm (.196) max. |
| Operating temperature | -20 °C to +55 °C |
| Total travel | NO : 4.5 (.177) +/- 0.3 (.011)NC : 3.5 (.137) +/- 0.3 (.011) |
| Max. current/voltage rating with resistive load | - silver contacts (A) : 4 A 250 VAC - 8 A 125 VAC - 4 A 24 VDC - 8 A 12 VDC- silver plated copper contacts (C) : 2 A 250 VAC - 3 A 125 VAC - 2 A 24 VDC - 3 A 12 VDC |
| Electrical Functions | Normally Open (NO) |
The APEMPanel Switches 1213C3 is presented using the documented product characteristics available for this model.
| Feature | Specification |
|---|---|
| Insulation resistance | 1,000 MΩ min. at 500 VDC |
| Dielectric strength | 2,000 Vrms 50 Hz min. between terminals3,000 Vrms 50 Hz min. between terminals and frame |
| Torque | 1.50 Nm (1.10 Ft.lb) max. applied to nut |
| Panel thickness | 5 mm (.196) max. |
| Operating temperature | -20 °C to +55 °C |
| Total travel | NO : 4.5 (.177) +/- 0.3 (.011)NC : 3.5 (.137) +/- 0.3 (.011) |
| Max. current/voltage rating with resistive load | - silver contacts (A) : 4 A 250 VAC - 8 A 125 VAC - 4 A 24 VDC - 8 A 12 VDC- silver plated copper contacts (C) : 2 A 250 VAC - 3 A 125 VAC - 2 A 24 VDC - 3 A 12 VDC |
| Electrical Functions | Normally Open (NO) |