Explore performance details, construction highlights, applications, and technical information in one clear overview.
LC1 is a Hanyoung NUX counter / timer for counting events and controlling time-based operations. Its model configuration determines the input method, timing or counting range, display and output functions, with model information of LC1 | LC1-F. Input condition: ▪Remaining voltage when disconnected : Max. 0.7 V ▪Max impedance when disconnected : Max. 10 kΩ ▪Min impedance when connected : Min. 1 MΩ | ▪HIGH : 24 - 240 V a.c. / 6 - 240 V d.c. ▪LOW : 0 - 2 V a.c. / 0 - 2.4 V d.c.; Computation speed: 1 cps / 30 cps / 100 cps / 1 kcps | 20 cps (fixed); Displaying type: LCD 7 segment reflection type, alphabet height 8.7 mm Black; Displaying digits: 8 digits.
The operating range, signal conditions, display format, computation speed and connection method should be checked against the machine sequence before installation. External setting switch: ※ ①SW1, ※ ② SW2 | ※ ①SW1; External connection: terminal block (4pin); Size: 48 (W) X 24 (H) mm; Weight: approx. 58 g (exclude the weight of box).
Key strengths of the LC1 come from the combination of its functional configuration and practical installation specifications. The following characteristics highlight the values that matter most when comparing the product with equipment requirements.
Computation speed: 1 cps / 30 cps / 100 cps / 1 kcps | 20 cps (fixed); Input method: non-voltage input | voltage input (free voltage); Power: No (run by battery, replacing possible); Displaying type: LCD 7 segment reflection type, alphabet height 8.7 mm Black; Battery life: more than 7 years (approx. 25 ℃).
The LC1 technical characteristics define the supported input conditions, counting or timing range, display resolution, computation speed and output behaviour. These values determine how the unit responds to machine signals. Computation speed: 1 cps / 30 cps / 100 cps / 1 kcps | 20 cps (fixed); Input method: non-voltage input | voltage input (free voltage); Power: No (run by battery, replacing possible); Displaying type: LCD 7 segment reflection type, alphabet height 8.7 mm Black.
Additional technical characteristics include Battery life: more than 7 years (approx. 25 ℃); External connection: terminal block (4pin); Input condition: ▪Remaining voltage when disconnected : Max. 0.7 V ▪Max impedance when disconnected : Max. 10 kΩ ▪Min impedance when connected : Min. 1 MΩ | ▪HIGH : 24 - 240 V a.c. / 6 - 240 V d.c. ▪LOW : 0 - 2 V a.c. / 0 - 2.4 V d.c..
The physical design of LC1 should be considered together with the installation environment and the available mounting or display arrangement. Insulation resistance: Min. 100 MΩ (500 V d.C. mega standard, between the electric conduction terminal and exposed non - charging metal part); Shock: Dura bility | 300 m/s² (approx 30G) each direction of X · Y · Z 3 times; Ambient temperature: -10 ~ 55 ℃ (no dew condensation, no icing); Storage temperature: -25 ~ 65 ℃ (no dew condensation, no icing).
Further construction and environmental details include Ambient humidity: 35 ~ 85 % R.H..
Integration of LC1 begins with matching its connection, input or control signal and output requirements to the surrounding equipment. Computation speed: 1 cps / 30 cps / 100 cps / 1 kcps | 20 cps (fixed); Input method: non-voltage input | voltage input (free voltage); Power: No (run by battery, replacing possible); Displaying type: LCD 7 segment reflection type, alphabet height 8.7 mm Black.
Additional operating and interface details include Battery life: more than 7 years (approx. 25 ℃); External connection: terminal block (4pin); Input condition: ▪Remaining voltage when disconnected : Max. 0.7 V ▪Max impedance when disconnected : Max. 10 kΩ ▪Min impedance when connected : Min. 1 MΩ | ▪HIGH : 24 - 240 V a.c. / 6 - 240 V d.c. ▪LOW : 0 - 2 V a.c. / 0 - 2.4 V d.c.. These values provide a practical reference for wiring, setup and normal operation within the selected configuration.
Choose LC1 by confirming the exact model or configuration against the required operating conditions. The available model information is LC1 | LC1-F. Model: LC1 | LC1-F; Computation speed: 1 cps / 30 cps / 100 cps / 1 kcps | 20 cps (fixed); Input method: non-voltage input | voltage input (free voltage); Power: No (run by battery, replacing possible).
Before installation, confirm Displaying type: LCD 7 segment reflection type, alphabet height 8.7 mm Black; Battery life: more than 7 years (approx. 25 ℃); External connection: terminal block (4pin). Matching the model, electrical ratings, signal requirements, physical arrangement and environmental limits helps keep the product within its specified operating conditions.
| Specification | Details |
|---|---|
| Model | LC1 | LC1-F |
| Input method | non-voltage input | voltage input (free voltage) |
| Power | No (run by battery, replacing possible) |
| Size | 48 (W) X 24 (H) mm |
| Operation method | Up only |
| Computation speed | 1 cps / 30 cps / 100 cps / 1 kcps | 20 cps (fixed) |
| Input condition | ▪Remaining voltage when disconnected : Max. 0.7 V ▪Max impedance when disconnected : Max. 10 kΩ ▪Min impedance when connected : Min. 1 MΩ | ▪HIGH : 24 - 240 V a.c. / 6 - 240 V d.c. ▪LOW : 0 - 2 V a.c. / 0 - 2.4 V d.c. |
| RESET | Input type | non-voltage input |
| Min signal width | Min. 20 ms |
| Battery life | more than 7 years (approx. 25 ℃) |
| External setting switch | ※ ①SW1, ※ ② SW2 | ※ ①SW1 |
| External connection | terminal block (4pin) |
| Displaying type | LCD 7 segment reflection type, alphabet height 8.7 mm Black |
| Displaying digits | 8 digits |
| Insulation resistance | Min. 100 MΩ (500 V d.C. mega standard, between the electric conduction terminal and exposed non - charging metal part) |
| Dielectric strenghth | 2000 V a.c. (50/60 Hz for 1 min, between the electric conduction terminal and exposed non-charging metal part) |
| Vibra tion | Dura bility | 10 - 55 Hz double amplitude 0.75 mm each direction of X · Y · Z for 2 hour |
| mal function | 10 - 55 Hz double amplitude 0.5 mm each direction of X · Y · Z for 10 min |
| Shock | Dura bility | 300 m/s² (approx 30G) each direction of X · Y · Z 3 times |
| mal function | 100 m/s² (approx 10G) each direction of X · Y · Z 3 times |
| Ambient temperature | -10 ~ 55 ℃ (no dew condensation, no icing) |
| Storage temperature | -25 ~ 65 ℃ (no dew condensation, no icing) |
| Ambient humidity | 35 ~ 85 % R.H. |
| Protective structure | IP66 (front side) |
| Weight | approx. 58 g (exclude the weight of box) |
| No | Type | Category | Title | File |
| 1 | Manual > Instruction Manual | Counter / Timer | LC1 Instruction Manual |
| 2 | Manual > Catalogue | Counter / Timer | LT1 / LC1 Catalogue |
| 1 | CAD > 2D | Counter / Timer | LC1 (2D) |
| 2 | CAD > 3D | Counter / Timer | LC1 (3D) |
| No | Mark | Category | Title | File |
| 1 | Certification > CE | Counter / Timer | LC1, LT1 (EMC) |
| 2 | Certification > CE | Counter / Timer | LC1, LT1 (LVD) |
| â–ªRemaining voltage when disconnected | Max. 0.7 V |