Explore performance details, construction highlights, applications, and technical information in one clear overview.
Findeva Knockers FKL-200 in is a pneumatic FKL knocker designed to deliver controlled impact to container and process-equipment walls. The FKL in design provides variable impact force and interval for removing adhering material from silos, chutes, filter outlets, reactors and pipelines.
The Knockers FKL-200 in supports single or interval impact operation. Impact force is adjusted through the control-bore arrangement, while the interval mode uses a throttle valve to control the time between impacts.
The model has a minimum operating pressure of 5.3 bar, control settings at 5.3, 6.7 and 8.0 bar, and a single-impact operating-pressure range of 2.0–8.0 bar. Energy per impact is 100–280 Nm and impulse per impact is 28.8–80.5 Ns.
The FKL in construction uses hard-anodized aluminium alloy for the housing/baseplate, an Ematal-covered cap and flange, a steel piston and compression spring. Standard versions operate from 10°C to 120°C, with special versions available for -40°C to 150°C.
| Brand | Findeva |
|---|---|
| Product family | FKL in Pneumatic Knocker |
| Model | Knockers FKL-200 in |
| Minimum operating pressure | 5.3 bar |
| Control-bore pressure settings | 5.3, 6.7, 8.0 bar |
| Operating pressure, single impact | 2.0–8.0 bar |
| Energy per impact | 100–280 Nm |
| Impulse per impact | 28.8–80.5 Ns |
| Stroke frequency | max. 10 min⁻¹ |
| Air consumption | 2.2–3.3 l/impact |
| Maximum wall thickness | 15 mm |
| Weight | 14.80 kg |
Removing adhering or compacted material from silos, hoppers, chutes, filter outlets, reactors, pipelines and other process containers.
The Knockers FKL-200 in is designed for compressed-air operation within the published Findeva operating range. Its model-specific construction and pneumatic characteristics provide controlled vibration or impact for material-flow and process equipment.
| Brand | Findeva |
|---|---|
| Product family | FKL in Pneumatic Knocker |
| Model | Knockers FKL-200 in |
| Minimum operating pressure | 5.3 bar |
| Control-bore pressure settings | 5.3, 6.7, 8.0 bar |
| Operating pressure, single impact | 2.0–8.0 bar |
| Energy per impact | 100–280 Nm |
| Impulse per impact | 28.8–80.5 Ns |
| Stroke frequency | max. 10 min⁻¹ |
| Air consumption | 2.2–3.3 l/impact |
| Maximum wall thickness | 15 mm |
| Weight | 14.80 kg |