The Vacuum Generator VX Manifold Individual Exhaust Port Type is a multitasking vacuum generator designed specifically for use in secondary battery manufacturing processes. It enables precise, responsive control of vacuum operations by supporting high cycle performance and rapid response to solenoid valve actuation, ensuring efficient and reliable operation during critical stages of production.
The unit is constructed without any copper-based metallic materials in its flow paths, eliminating potential contamination risks. Sealing components utilize low-concentration ozone-resistant HNBR or FKM rubber materials, which provide durability under demanding environmental conditions. The body is made from PVFM (polyvinyl formal), a material selected for its chemical resistance and long-term stability in vacuum environments.
The Vacuum Generator VX features an individual exhaust port design that allows for direct integration into specific process lines. It supports two installation methods, offering flexibility in system layout and mounting options. Pressure sensing is available in three configurations, with the pressure detection type being a diffused semiconductor switch capable of settings ranging from -99 to 0 kPa.
The unit operates within an air medium compliant with JIS B 8392-1 (Class 1.2.1 to 2.4.3). It functions reliably across an operating pressure range of 0.3 to 0.7 MPa or -100 to 0 kPa, and maintains performance between 5°C and 50°C without freezing. Humidity levels from 35% to 85% RH are supported with no dew condensation. The system is tested at a proof pressure of 1.05 MPa for the air supply circuit and 0.2 MPa for the vacuum circuit.
The Vacuum Generator VX offers two distinct valve configurations: normally closed and double-piloted, each providing different operational characteristics depending on process requirements. The unit is available with a single or dual pressure setting option, and operates on a wide range of power supplies including 24 VDC ±10%, 100 VAC ±10%, or 12 to 24 VDC ±10% (with ripple P-P ≤ 10%).
Installation is supported via two selectable methods, allowing integration into existing systems with minimal modification. The unit is designed for compatibility with standard vacuum circuits and can be directly connected to process lines through its individual exhaust port. Its lightweight and compact design ensures ease of installation while maintaining high performance in space-constrained environments.
| Specification | Details |
|---|---|
| Fluid medium | Air [JIS B 8392-1: (Class 1.2.1 to 2.4.3)] |
| Operating pressure range | 0.3 to 0.7 MPa | -100 to 0 kPa |
| Operating temperature range | 5 to 50°C (No freezing) |
| Operating humidity range | 35 to 85% RH (No dew condensation) |
| Proof pressure (air supply circuit) | 1.05 MPa |
| Proof pressure (vacuum circuit) | 0.2 MPa |
| Rated voltage | 24 VDC ±10% | 100 VAC ±10% | 12 to 24 VDC ±10%, ripple (P-P): 10% max. |
| Operating type | Indirect operation by pilot valve | Direct-operated poppet |
| Valve type | Normally closed | Double-piloted *1 |
| Response time (OFF→ON) | 24 VDC: 7 msec (-S3 spec.: 8 msec) / 100 VAC: 10 msec (-S3 spec.: 11 msec) | 24 VDC: 8 msec (-S3 spec.: 6.5 msec) / 100 VAC: 11 msec (-S3 spec.: 9.5 msec) | 3.5 msec (24 VDC) / 8 msec (100 VAC) |
| Response time (ON→OFF) | 24 VDC: 14.5 msec (-S3 spec.: 23.5 msec) / 100 VAC: 16 msec (-S3 spec.: 29.5 msec) | 24 VDC: 23.5 msec (-S3 spec.: 18.5 msec) / 100 VAC: 29.5 msec (-S3 spec.: 15 msec) | 3 msec (24 VDC) / 14 msec (100 VAC) |
| Element material | PVFM (polyvinyl formal) |
| Blow-off air flow rate: Normally closed | 0 to 7.5 L/min [ANR] (Supply pressure: 0.5 MPa) |
| Blow-off air flow rate: Double-piloted | 0.2 to 2 L/min [ANR] (Supply pressure: 0.5 MPa) |
| Current consumption | 40 mA max. | 15 mA max. |
| Pressure detection | Diffused semiconductor pressure switch |
| Pressure setting range | -99 to 0 kPa |
| Proof pressure | 0.2 MPa |
| Power supply voltage | 12 to 24 VDC ±10%, Ripple (P-P): 10% max. |
| No. of pressure settings | 2 | 1 |
| Switch output | NPN open collector (30 V, 80 mA max., Residual voltage: 0.8 V max.) | NPN open collector (30 V 80 mA max., residual voltage: 0.8 V max.) |
| Response time | Approx. 2 msec |
| Analog output: Output voltage | 1 to 5 V |
| Analog output: Zero-point voltage | 1 ±0.1 V |
| Analog output: Span voltage | 4 ±0.1 V |
| Analog output: Output current | 1 mA max. (Load resistance: 5 kΩ min.) |
| Analog output: Linearity/Hysteresis | ±0.5% F.S. max. (Standard temp.: 25°C) |
| Metric size (mm) | φ3, φ4, φ6 | φ4, φ6 | φ4, φ6, φ8, φ10 | φ6 | φ6, φ8, φ10 |
| Material restriction | No copper-based metallic material is used in flow paths |
| Pressure sensor configuration | Pressure sensor with legible LED display (2 switch outputs type and 1 switch output + 1 analog output) and cost-optimized analog type |