The Safety Light Curtains - SH4 Cascade - 957920120 (SH4-30-1350-C-5-5) is a industrial product from Datasensing. The documented values above identify the exact configuration and are the basis for technical selection and system integration.
Engineered for industrial use, this cascade model integrates seamlessly with Datasensing SH4 Standard Muting or SH4 Advanced systems. Its robust construction and precise specifications ensure reliable safety performance in harsh conditions.
The documented configuration includes Resolution: 30 mm; Response time: 12 ms; Improved operating range: 20 m; Nominal sensing distance: 0.2 … 20 m; Emission: Infrared LED (850 nm wavelength).
The documented configuration includes Operating Voltage: 24 Vdc ± 20%; Cabel Length (Power Supply/Output): ≤ 30 m; Cable Length for Master Slave Interconnections: ≤ 10 m; Load current: ≤ 250mA each output; Power Consumption - Receiver: ≤ 4W (no load); Power Consumption - Emitter: ≤ 3,5W.
The documented configuration includes Material: Painted aluminum / MAKROLON AR 7099 Clear PC / PBT; Storage temperature: -30 …+70 °C; Dimensions: 35x40x1359 mm; Operating Temperature: -30…+55°C; Mechanical Protection: IP65, IP 67 (EN 60529); Storage temperature: 30 …+70 °C; Operating Temperature: 30…+55°C; Standard "L" Mounting Brackets: 6 pcs kit.
The documented configuration includes controlled height: 1350 mm; Humidity: 15 … 95 % (no condensation).
The documented configuration includes Available functions: Cascade Slave Unit, to be used with SH4 STANDARD MUTING or SH4 ADVANCED; Functions: Finger protection res. 14 mm slave; Function Principle: Emitter + Receiver; Application: Function Principle.
The documented configuration includes Connections: M12-5 poles pigtail (emitter) M12-5 poles pigtail (receiver); Effective Aperture Angle: ≤ ±2.5°; Description: Compact no-dead-zone CASCADE; Type: Type 4 safety light curtain (Sl); Interference to external light: According to IEC 61496-2; Capacitive Load: ≤ 1µF; Vibrations: 10 mm / 3 g, 5 … 150 Hz frequency (EN 60068-2-6 / Class 3M7 IEC TR 60721-4-3); Shocks: 25 g x 6 ms x 600 (EN 60068-2-27 / Class 3M7 IEC TR 60721-4-3).
The documented configuration includes Shocks and vibrations: 10 mm / 3g, 5 to 150 Hz frequency (EN 60068-2-6 / Class 3M7 IEC TR 60721-4-3); 25g x 6 ms x 600 (EN 60068-2-27 / Class 3M7 IEC TR 60721-4-3); SH4 CASCADE Res = 30 mm h: 1350 mm 5+5 poles.
| Feature | Specification |
|---|---|
| Resolution | 30 mm |
| Response time | 12 ms |
| Operating Voltage | 24 Vdc ± 20% |
| Cabel Length (Power Supply/Output) | ≤ 30 m |
| Cable Length for Master Slave Interconnections | ≤ 10 m |
| Material | Painted aluminum / MAKROLON AR 7099 Clear PC / PBT |
| Connections | M12-5 poles pigtail (emitter) M12-5 poles pigtail (receiver) |
| Storage temperature | -30 …+70 °C |
| Dimensions | 35x40x1359 mm |
| Operating Temperature | -30…+55°C |
| Mechanical Protection | IP65, IP 67 (EN 60529) |
| Storage temperature | 30 …+70 °C |
| Operating Temperature | 30…+55°C |
| Improved operating range | 20 m |
| Standard "L" Mounting Brackets | 6 pcs kit |
| Nominal sensing distance | 0.2 … 20 m |
| controlled height | 1350 mm |
| Effective Aperture Angle | ≤ ±2.5° |
| Available functions | Cascade Slave Unit, to be used with SH4 STANDARD MUTING or SH4 ADVANCED |
| Description | Compact no-dead-zone CASCADE |
| Functions | Finger protection res. 14 mm slave |
| Type | Type 4 safety light curtain (Sl) |
| Load current | ≤ 250mA each output |
| Emission | Infrared LED (850 nm wavelength) |
| Interference to external light | According to IEC 61496-2 |
| Power Consumption - Receiver | ≤ 4W (no load) |
| Power Consumption - Emitter | ≤ 3,5W |
| Capacitive Load | ≤ 1µF |
| Vibrations | 10 mm / 3 g, 5 … 150 Hz frequency (EN 60068-2-6 / Class 3M7 IEC TR 60721-4-3) |
| Shocks | 25 g x 6 ms x 600 (EN 60068-2-27 / Class 3M7 IEC TR 60721-4-3) |
| Shocks and vibrations | 10 mm / 3g, 5 to 150 Hz frequency (EN 60068-2-6 / Class 3M7 IEC TR 60721-4-3); 25g x 6 ms x 600 (EN 60068-2-27 / Class 3M7 IEC TR 60721-4-3) |
| Humidity | 15 … 95 % (no condensation) |
| SH4 CASCADE Res = 30 mm h | 1350 mm 5+5 poles |
| Function Principle | Emitter + Receiver |
| Application | Function Principle |