DATASENSING Sensors Safety light Curtains

Safety Light Curtains - SH4 Cascade - 957920119 (SH4-30-1200-C-5-5)

Datasensing SH4 Cascade Safety Light Curtain (957920119) delivers precise 30mm resolution with 12ms response time. Ideal for industrial automation, this 35x40x1209mm unit operates within -30°C to +55°C and features M12-5 pole connections for robust integration.
  • Brand DATASENSING
  • Category Sensors
  • Subcategory Safety light Curtains
Interested in this product? Safety Light Curtains - SH4 Cascade - 957920119 (SH4-30-1200-C-5-5)
Product insights

Everything you need to evaluate this product

Explore performance details, construction highlights, applications, and technical information in one clear overview.

Quality assured Technical details Industrial use Expert support

Product Summary

The Safety Light Curtains - SH4 Cascade - 957920119 (SH4-30-1200-C-5-5) is a industrial product from Datasensing. The documented values above identify the exact configuration and are the basis for technical selection and system integration.

Datasensing SH4 Cascade Safety Light Curtain

  • Operating Voltage: 24 Vdc ± 20%
  • Cable Lengths: Power supply/output ≤ 30 m; Master slave interconnections ≤ 10 m
  • Material Construction: Painted aluminum / MAKROLON AR 7099 Clear PC / PBT
  • Environmental Range: Operating temperature -30°C to +55°C; Storage temperature -30°C to +70°C
  • Dimensions: 35 x 40 x 1209 mm

With M12-5 pole pigtail connections for both emitter and receiver, this cascade model integrates seamlessly with Datasensing SH4 Standard Muting or SH4 Advanced systems. Its robust construction ensures long-term reliability in industrial settings.

Performance

The documented configuration includes Resolution: 30 mm; Response time: 12 ms; Improved operating range: 20 m; Nominal sensing distance: 0.2 … 20 m; Emission: Infrared LED (850 nm wavelength).

Electrical and Interface

The documented configuration includes Operating Voltage: 24 Vdc ± 20%; Cabel Length (Power Supply/Output): ≤ 30 m; Cable Length for Master Slave Interconnections: ≤ 10 m; Load current: ≤ 250mA each output; Power Consumption - Receiver: ≤ 4W (no load); Power Consumption - Emitter: ≤ 3,5W.

Mechanical and Environmental

The documented configuration includes Material: Painted aluminum / MAKROLON AR 7099 Clear PC / PBT; Storage temperature: -30 …+70 °C; Dimensions: 35x40x1209 mm; Operating Temperature: -30…+55°C; Mechanical Protection: IP65, IP 67 (EN 60529); Storage temperature: 30 …+70 °C; Operating Temperature: 30…+55°C; Standard "L" Mounting Brackets: 6 pcs kit.

Mechanical and Environmental – Additional Details

The documented configuration includes controlled height: 1200 mm; Humidity: 15 … 95 % (no condensation).

Configuration and Functional

The documented configuration includes Available functions: Cascade Slave Unit, to be used with SH4 STANDARD MUTING or SH4 ADVANCED; Functions: Finger protection res. 14 mm slave; Function Principle: Emitter + Receiver; Application: Function Principle.

General

The documented configuration includes Connections: M12-5 poles pigtail (emitter) M12-5 poles pigtail (receiver); Effective Aperture Angle: ≤ ±2.5°; Description: Compact no-dead-zone CASCADE; Type: Type 4 safety light curtain (Sl); Interference to external light: According to IEC 61496-2; Capacitive Load: ≤ 1µF; Vibrations: 10 mm / 3 g, 5 … 150 Hz frequency (EN 60068-2-6 / Class 3M7 IEC TR 60721-4-3); Shocks: 25 g x 6 ms x 600 (EN 60068-2-27 / Class 3M7 IEC TR 60721-4-3).

General – Additional Details

The documented configuration includes Shocks and vibrations: 10 mm / 3g, 5 to 150 Hz frequency (EN 60068-2-6 / Class 3M7 IEC TR 60721-4-3); 25g x 6 ms x 600 (EN 60068-2-27 / Class 3M7 IEC TR 60721-4-3); SH4 CASCADE Res = 30 mm h: 1200 mm 5+5 poles.

FeatureSpecification
Resolution30 mm
Response time12 ms
Operating Voltage24 Vdc ± 20%
Cabel Length (Power Supply/Output)≤ 30 m
Cable Length for Master Slave Interconnections≤ 10 m
MaterialPainted aluminum / MAKROLON AR 7099 Clear PC / PBT
ConnectionsM12-5 poles pigtail (emitter) M12-5 poles pigtail (receiver)
Storage temperature-30 …+70 °C
Dimensions35x40x1209 mm
Operating Temperature-30…+55°C
Mechanical ProtectionIP65, IP 67 (EN 60529)
Storage temperature30 …+70 °C
Operating Temperature30…+55°C
Improved operating range20 m
Standard "L" Mounting Brackets6 pcs kit
Nominal sensing distance0.2 … 20 m
controlled height1200 mm
Effective Aperture Angle≤ ±2.5°
Available functionsCascade Slave Unit, to be used with SH4 STANDARD MUTING or SH4 ADVANCED
DescriptionCompact no-dead-zone CASCADE
FunctionsFinger protection res. 14 mm slave
TypeType 4 safety light curtain (Sl)
Load current≤ 250mA each output
EmissionInfrared LED (850 nm wavelength)
Interference to external lightAccording to IEC 61496-2
Power Consumption - Receiver≤ 4W (no load)
Power Consumption - Emitter≤ 3,5W
Capacitive Load≤ 1µF
Vibrations10 mm / 3 g, 5 … 150 Hz frequency (EN 60068-2-6 / Class 3M7 IEC TR 60721-4-3)
Shocks25 g x 6 ms x 600 (EN 60068-2-27 / Class 3M7 IEC TR 60721-4-3)
Shocks and vibrations10 mm / 3g, 5 to 150 Hz frequency (EN 60068-2-6 / Class 3M7 IEC TR 60721-4-3); 25g x 6 ms x 600 (EN 60068-2-27 / Class 3M7 IEC TR 60721-4-3)
Humidity15 … 95 % (no condensation)
SH4 CASCADE Res = 30 mm h1200 mm 5+5 poles
Function PrincipleEmitter + Receiver
ApplicationFunction Principle