DATASENSING Sensors Safety light Curtains

Safety Light Curtains - SH4 Cascade - 957920036 (SH4-14-1350-C-5-5)

Datasensing SH4 Cascade Safety Light Curtain (957920036) delivers precise 14mm resolution with 24Vdc ±20% operating voltage. Features IP65/67 protection, ≤30m cable length for power and ≤10m for master-slave interconnections, and robust painted aluminum construction for -30°C to +55°C operation.
  • Brand DATASENSING
  • Category Sensors
  • Subcategory Safety light Curtains
Interested in this product? Safety Light Curtains - SH4 Cascade - 957920036 (SH4-14-1350-C-5-5)
Product insights

Everything you need to evaluate this product

Explore performance details, construction highlights, applications, and technical information in one clear overview.

Quality assured Technical details Industrial use Expert support

Product Summary

The Safety Light Curtains - SH4 Cascade - 957920036 (SH4-14-1350-C-5-5) is a industrial product from Datasensing. The documented values above identify the exact configuration and are the basis for technical selection and system integration.

Datasensing SH4 Cascade Safety Light Curtain

The Datasensing SH4 Cascade Safety Light Curtain (model 957920036) is a high-precision industrial safety device designed for reliable motion detection in demanding environments. It operates with a 14mm resolution and 24Vdc ±20% voltage, ensuring accurate safety monitoring while maintaining robust performance.

  • Key Specifications: IP65/67 (EN 60529) mechanical protection, ≤30m power supply/output cable length, ≤10m master-slave interconnection cable length
  • Material & Construction: Painted aluminum body with MAKROLON AR 7099 clear PC and PBT components, suitable for -30°C to +70°C storage and -30°C to +55°C operation
  • Connectivity: M12-5 pole pigtail connectors for both emitter and receiver, enabling seamless integration with SH4 Standard Muting or SH4 Advanced systems

Performance

The documented configuration includes Resolution: 14 mm; Improved operating range: 10 m; Nominal sensing distance: 0.2 … 10 m; Emission: Infrared LED (850 nm wavelength).

Electrical and Interface

The documented configuration includes Operating Voltage: 24 Vdc ± 20%; Cabel Length (Power Supply/Output): ≤ 30 m; Cable Length for Master Slave Interconnections: ≤ 10 m; Load current: ≤ 250mA each output; Power Consumption - Receiver: ≤ 4W (no load); Power Consumption - Emitter: ≤ 3,5W.

Mechanical and Environmental

The documented configuration includes Material: Painted aluminum / MAKROLON AR 7099 Clear PC / PBT; Storage temperature: -30 …+70 °C; Dimensions: 35x40x1359 mm; Operating Temperature: -30…+55°C; Mechanical Protection: IP65, IP 67 (EN 60529); Storage temperature: 30 …+70 °C; Operating Temperature: 30…+55°C; Standard "L" Mounting Brackets: 6 pcs kit.

Mechanical and Environmental – Additional Details

The documented configuration includes controlled height: 1350 mm; Humidity: 15 … 95 % (no condensation).

Configuration and Functional

The documented configuration includes Available functions: Cascade Slave Unit, to be used with SH4 STANDARD MUTING or SH4 ADVANCED; Functions: Finger protection res. 14 mm slave; Function Principle: Emitter + Receiver; Application: Function Principle.

General

The documented configuration includes Connections: M12-5 poles pigtail (emitter) M12-5 poles pigtail (receiver); Effective Aperture Angle: ≤ ±2.5°; Description: Compact no-dead-zone CASCADE; Type: Type 4 safety light curtain (Sl); Interference to external light: According to IEC 61496-2; Capacitive Load: ≤ 1µF; Vibrations: 10 mm / 3 g, 5 … 150 Hz frequency (EN 60068-2-6 / Class 3M7 IEC TR 60721-4-3); Shocks: 25 g x 6 ms x 600 (EN 60068-2-27 / Class 3M7 IEC TR 60721-4-3).

General – Additional Details

The documented configuration includes Shocks and vibrations: 10 mm / 3g, 5 to 150 Hz frequency (EN 60068-2-6 / Class 3M7 IEC TR 60721-4-3); 25g x 6 ms x 600 (EN 60068-2-27 / Class 3M7 IEC TR 60721-4-3); SH4 CASCADE Res = 14 mm h: 1350 mm 5+5 poles.

FeatureSpecification
Resolution14 mm
Operating Voltage24 Vdc ± 20%
Cabel Length (Power Supply/Output)≤ 30 m
Cable Length for Master Slave Interconnections≤ 10 m
MaterialPainted aluminum / MAKROLON AR 7099 Clear PC / PBT
ConnectionsM12-5 poles pigtail (emitter) M12-5 poles pigtail (receiver)
Storage temperature-30 …+70 °C
Dimensions35x40x1359 mm
Operating Temperature-30…+55°C
Mechanical ProtectionIP65, IP 67 (EN 60529)
Storage temperature30 …+70 °C
Operating Temperature30…+55°C
Improved operating range10 m
Standard "L" Mounting Brackets6 pcs kit
Nominal sensing distance0.2 … 10 m
controlled height1350 mm
Effective Aperture Angle≤ ±2.5°
Available functionsCascade Slave Unit, to be used with SH4 STANDARD MUTING or SH4 ADVANCED
DescriptionCompact no-dead-zone CASCADE
FunctionsFinger protection res. 14 mm slave
TypeType 4 safety light curtain (Sl)
Load current≤ 250mA each output
EmissionInfrared LED (850 nm wavelength)
Interference to external lightAccording to IEC 61496-2
Power Consumption - Receiver≤ 4W (no load)
Power Consumption - Emitter≤ 3,5W
Capacitive Load≤ 1µF
Vibrations10 mm / 3 g, 5 … 150 Hz frequency (EN 60068-2-6 / Class 3M7 IEC TR 60721-4-3)
Shocks25 g x 6 ms x 600 (EN 60068-2-27 / Class 3M7 IEC TR 60721-4-3)
Shocks and vibrations10 mm / 3g, 5 to 150 Hz frequency (EN 60068-2-6 / Class 3M7 IEC TR 60721-4-3); 25g x 6 ms x 600 (EN 60068-2-27 / Class 3M7 IEC TR 60721-4-3)
Humidity15 … 95 % (no condensation)
SH4 CASCADE Res = 14 mm h1350 mm 5+5 poles
Function PrincipleEmitter + Receiver
ApplicationFunction Principle
Shop by category
Category

Browse product families and jump into the exact catalog section you need.

Product categories