NORGREN Pneumatics Filter Regulator Lubricator (FRL)

F82C-2GD-QP0

The NORGREN Excelon Plus Coalescing Filter F82C-2GD-QP0 is a manual drain coalescing filter designed for compressed air systems. Featuring a polycarbonate bowl with a 0.01 μm particle removal capability, it handles maximum inlet pressures up to 10 bar (145 psi) and maintains oil content below 0.01 mg/m³ at 21°C. The filter includes synthetic fibre and PE foam elements, a die-cast aluminium body, and a manual drain mechanism for precise oil separation in industrial air applications.
  • Brand NORGREN
  • Category Pneumatics
  • Subcategory Filter Regulator Lubricator (FRL)
Interested in this product? Excelon Plus Coalescing Filter, G1/4", manual drainCoalescingFilter: F82C-2GD-QP0
Product insights

Everything you need to evaluate this product

Explore performance details, construction highlights, applications, and technical information in one clear overview.

Quality assured Technical details Industrial use Expert support

Product Overview

F82C-2GD-QP0 is a NORGREN Excelon Plus Coalescing Filter, G1/4", manual drainCoalescingFilter: F82C-2GD-QP0 configuration.

Technical Specifications

Medium: Compressed air only. Maximum Inlet Pressure: Polycarbonate bowl. Filter Element: Synthetic fibre & PE foam. Port Size: G1/4, G3/8, 1/4 PTF, 3/8 PTF. Port Size: 3/8”. Port Size: 1/4”. Drain Type: Manual or automatic. Operating Temperature: Polycarbonate bowl. Flow: 5.5 dm³/s - Maximum flow to. Materials: Body: Die cast aluminium. Remaining Oil Content: 0,01 mg/m3 at +21°C (+69°F). Maximum Supply Pressure: Polycarbonate bowl: 10 bar (145 psi) Metal bowl: 17 bar (246 psi). Particle Removal: To 0,01 μm. Flow: 5.5 dm³/s - Maximum flow to maintain stated oil removal performance at chal lenge rate of 4 mg/m³, operating pressure: 6,3 bar (91 psi). Drain Type: Manual or automatic Automatic drain operating conditions (float operated): Bowl pressure required to close drain: > 0,35 bar (5 psi) Bowl pressure required to open drain: ≤ 0,2 bar (2.9 psi) Minimum air flow required to. Operating Temperature: Polycarbonate bowl: -10 ... +60°C (+14 ... +140°F) Metal bowl: -20 ... +65°C (-4 ... +149°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Note: Install an F82G filter with a 5 μm. ATEX: Filters F82 are in conformity with Atex 2014/34/EU II 2 GD Ex h IIC T6 Gb EX h IIIC T85°C Db. Materials: Body: Die cast aluminium Body covers: ABS Transparent Bowl : Polycarbonate with Polypropylene Guard. Metal Bowl: Die cast Zinc with PA liquid level indicator lens. Filter Element: Synthetic fibre & PE foam Bowl ‘o'- ring: Chloroprene Elastomers: NBR. Particle Removal: - Double safety lock bowl - Metal bowl with prismatic liquid level indicator lens - Light weight Polycarbonate bowl - Service indicator standard. Filter Element: 0,01µm 820044-50KIT Auto drain kit with metal Nut - Imperial 6000-61KIT Auto drain kit with metal Nut - Metric 6000-60KIT. Model: F82C-2GD-QP0. Port Size: G1/4. Drain Type: Manual. Bowl: Metal with level indicator. Weight: 0.25 kg. Shut-off Valve: With shut-off valve.

Product Selection

The selected configuration specifies Medium as Compressed air only. This value is part of the product definition and should be considered together with the other stated configuration details when selecting this model.

SpecificationValue
MediumCompressed air only
Maximum Inlet PressurePolycarbonate bowl
Filter ElementSynthetic fibre & PE foam
Port SizeG1/4, G3/8, 1/4 PTF, 3/8 PTF
Port Size3/8”
Port Size1/4”
Drain TypeManual or automatic
Operating TemperaturePolycarbonate bowl
Flow5.5 dm³/s - Maximum flow to
MaterialsBody: Die cast aluminium
Remaining Oil Content0,01 mg/m3 at +21°C (+69°F)
Maximum Supply PressurePolycarbonate bowl: 10 bar (145 psi) Metal bowl: 17 bar (246 psi)
Particle RemovalTo 0,01 μm
Flow5.5 dm³/s - Maximum flow to maintain stated oil removal performance at chal lenge rate of 4 mg/m³, operating pressure: 6,3 bar (91 psi)
Drain TypeManual or automatic Automatic drain operating conditions (float operated): Bowl pressure required to close drain: > 0,35 bar (5 psi) Bowl pressure required to open drain: ≤ 0,2 bar (2.9 psi) Minimum air flow required to
Operating TemperaturePolycarbonate bowl: -10 ... +60°C (+14 ... +140°F) Metal bowl: -20 ... +65°C (-4 ... +149°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Note: Install an F82G filter with a 5 μm
ATEXFilters F82 are in conformity with Atex 2014/34/EU II 2 GD Ex h IIC T6 Gb EX h IIIC T85°C Db
MaterialsBody: Die cast aluminium Body covers: ABS Transparent Bowl : Polycarbonate with Polypropylene Guard. Metal Bowl: Die cast Zinc with PA liquid level indicator lens
Filter ElementSynthetic fibre & PE foam Bowl ‘o'- ring: Chloroprene Elastomers: NBR
Particle Removal- Double safety lock bowl - Metal bowl with prismatic liquid level indicator lens - Light weight Polycarbonate bowl - Service indicator standard
Filter Element0,01µm 820044-50KIT Auto drain kit with metal Nut - Imperial 6000-61KIT Auto drain kit with metal Nut - Metric 6000-60KIT
ModelF82C-2GD-QP0
Port SizeG1/4
Drain TypeManual
BowlMetal with level indicator
Weight0.25 kg
Shut-off ValveWith shut-off valve
Shop by category
Category

Browse product families and jump into the exact catalog section you need.

Product categories