The IFM DD111S is a safety speed monitor designed for reliable monitoring of rotational and linear movement. It provides safety-related switching outputs for applications where machine speed must be monitored continuously. The device supports a low-frequency monitoring range suitable for slow-moving machinery. Its dual-channel monitoring concept supports high safety levels. The unit is suitable for applications requiring dependable overspeed monitoring.
Explore performance details, construction highlights, applications, and technical information in one clear overview.
The DD111S monitors speed through pulse signals from external sensors. Its frequency range of 0.1...99.9 Hz makes it suitable for low-speed applications. Two safety-related switching outputs provide redundant control signals. The device can also provide fault and diagnostic outputs. This enables the monitor to be integrated into machine safety systems.
The speed threshold can be configured through rotary switches without complex menu systems. Automatic or manual reset functions can be selected depending on the application. Startup and enable functions help control the monitoring process. LED indicators provide clear operating status information. DIN-rail installation makes integration into control cabinets straightforward.
Safety speed monitoring
0.1...99.9 Hz range
Two safety outputs
Fault output
Diagnostic output
Pulse input
24 V DC operation
Adjustable speed threshold
Automatic reset
Manual reset
Enable function
LED status indication
DIN-rail mounting
IP20 housing
High safety capability
Slow-speed conveyors
Fans
Rotating machines
Drive systems
Machine guarding
Material handling
Safety monitoring
Motor speed supervision
Belt-break detection
Overspeed monitoring
Industrial machinery
Motion control
| Specification | Details |
|---|---|
| Brand | IFM |
| Model | DD111S |
| Product Type | Safety Speed Monitor |
| Nominal Voltage | 24 V DC |
| Operating Voltage | 19.2...28.8 V DC |
| Current Consumption | ≤125 mA |
| Frequency Range | 0.1...99.9 Hz |
| Maximum Input Frequency | ≤2000 Hz |
| Pulse Inputs | 2 |
| Sensor Supply | 24 V DC |
| Safety Outputs | 2 floating switching outputs |
| Fault Output | PNP |
| Diagnostic Output | PNP |
| Output Current | Up to 20 mA for diagnostic outputs |
| Relay Contact Rating | Up to 6 A |
| Reset | Automatic / manual |
| Enable Function | Supported |
| Setting | Rotary switches |
| Protection | IP20 |
| Mounting | DIN rail |
| Housing | Polyamide |
| Connection | Screw terminals |
| Operating Temperature | -40...55 °C |
| Storage Temperature | -40...75 °C |
| Application | Safe speed monitoring |