IFM AL4142 is a PerformanceLine Ethernet field module with Modbus TCP communication and 16 digital inputs. It is designed for decentralized sensor connection in industrial automation applications. The module provides direct field-level communication with Modbus TCP controllers. Integrated counters support high-speed sensor pulse processing. Its PerformanceLine construction provides robust machine-side installation. IP67 protection supports use in demanding industrial environments.
Explore performance details, construction highlights, applications, and technical information in one clear overview.
AL4142 uses Modbus TCP over industrial Ethernet. It allows sensor signals to be transferred directly from the field module to the PLC. This decentralized architecture reduces long sensor wiring runs. The module can be positioned close to machines and sensors. Modbus TCP supports straightforward integration with compatible industrial controllers. It provides a practical field I/O solution for modern automation systems.
The 16 digital inputs support industrial binary sensors. Eight counter functions are integrated into the module. Counter frequency can reach 4500 Hz. Multiple counting modes provide flexible signal processing. M12 connections support reliable field wiring. IP67 protection provides protection against dust and temporary water exposure.
16 digital inputs
Modbus TCP communication
PerformanceLine design
Integrated high-frequency counters
8 counter channels
4500 Hz counting frequency
32-bit main counter
16-bit batch counter
IP67 protection
M12 connections
L-coded power connection
Daisy-chain capability
Short-circuit-protected inputs
Robust field housing
Decentralized I/O architecture
Modbus TCP automation
Machine control
Packaging equipment
Conveyor systems
Production monitoring
Industrial sensor networks
Pulse counting
Assembly machines
Factory automation
Machine status acquisition
| Specification | Details |
|---|---|
| Product Code | AL4142 |
| Series | PerformanceLine |
| Interface | Modbus TCP |
| Digital Inputs | 16 |
| Input Standard | IEC 61131-2 Type 2 |
| High Level | 11–30 V |
| Low Level | 0–5 V |
| Input Protection | Short-circuit protected |
| Counter Function | Yes |
| Counter Number | 8 |
| Counter Frequency | 4500 Hz |
| Main Counter | 32 bit |
| Batch Counter | 16 bit |
| Supply Voltage | 20–30 V DC |
| Power Connector | M12 L-coded |
| Daisy Chain | Yes |
| Ethernet Standard | 100Base-TX |
| Transmission Rate | 100 Mbit/s |
| Protocol | Modbus TCP |
| Protection | IP67 |
| Ambient Temperature | -25 to +60 °C |
| Storage Temperature | -25 to +85 °C |
| Humidity | Up to 90% |
| Housing | Polyamide |
| Connector | M12 |
| Mounting | Backplane |
| Dimensions | Approx. 208 × 59.3 × 38.4 mm |
| Application | Industrial field automation |