IFM AC508S is a safe AS-Interface ClassicLine module designed for OSSD-based safety applications with auxiliary power support. It integrates safety signal handling into a distributed AS-i architecture. The auxiliary supply arrangement supports applications requiring additional field power. The module provides local diagnostics for commissioning and troubleshooting. AC508S is suitable for demanding industrial machine-safety applications.
Explore performance details, construction highlights, applications, and technical information in one clear overview.
The AUX configuration provides an additional power path for suitable field devices. This can be important when safety devices or connected components require more power than the AS-i network should provide. Separating auxiliary power from communication can improve system flexibility. It also supports distributed installation strategies. Proper supply sizing must follow the manufacturer's specifications.
OSSD compatibility allows integration with electronic safety devices. The safety module can transmit safety states through the AS-i Safety at Work system. Distributed safety I/O reduces complex point-to-point wiring. Local diagnostics assist maintenance teams. The complete safety system should always be validated according to applicable standards.
Safe AS-i module
OSSD support
Two safety inputs
AUX supply
Two output functions
Two local output indicators
AS-i Safety at Work
IP67 field design
ClassicLine construction
Distributed safety I/O
LED diagnostics
Industrial machine safety
Safety light curtains
Electronic safety devices
Machine guarding
Robot cells
Emergency-stop systems
Packaging machines
Conveyor safety
Production equipment
Safety interlocking
Industrial automation
| Specification | Details |
|---|---|
| Product Code | AC508S |
| Product Type | Safe AS-i module |
| Product Family | ClassicLine |
| Safety Inputs | 2 SI |
| Auxiliary Supply | AUX |
| Outputs | 2 DOT |
| Local Outputs | 2 LO |
| OSSD | Supported |
| Safety Technology | AS-i Safety at Work |
| Safety Classification | SIL 3 / PL e Cat.4 class |
| Protection | IP67 |
| Communication | AS-i |
| Mounting | Quick mounting |
| Connection | Field connectors |
| Addressing | AS-i |
| Diagnostics | LED |
| Housing | ClassicLine |
| Installation | Field |
| Operating Voltage | Refer to datasheet |
| Auxiliary Voltage | Refer to datasheet |
| Ambient Temperature | Refer to datasheet |
| Dimensions | Refer to datasheet |
| Weight | Refer to datasheet |
| Manufacturer | IFM electronic |
| Pack Quantity | 1 piece |