AC011S is a key-release emergency-stop operating element with integrated AS-i communication. It is designed for safety-related emergency-stop applications in industrial machinery. The key-release mechanism provides controlled resetting after an emergency-stop event. Its IP67 protection makes it suitable for demanding industrial installations. AC011S can be integrated into AS-i Safety at Work systems for distributed safety monitoring.
Explore performance details, construction highlights, applications, and technical information in one clear overview.
AC011S uses a key-release mechanism to control resetting after emergency-stop activation. This can help prevent unintended restart following a safety event. The operator must perform the required reset action before the machine can return to operation. The design is useful where controlled reset procedures are important. It supports structured machine-safety workflows.
The integrated AS-i connection allows the emergency-stop signal to be incorporated into an AS-i safety network. This can reduce additional wiring between individual safety devices and the control architecture. Safety status can be monitored through the AS-i system. The device is suitable for distributed machine-safety installations. It can therefore support larger automated systems with multiple safety points.
AC011S has an IP67 protection rating according to IFM's operating-element listing. The robust operating concept is intended for industrial machinery. The device can be installed at accessible operator locations. It is suitable for production, packaging and automated handling equipment. Correct installation and safety validation must be completed according to the machine's risk assessment.
Key-release E-STOP
Integrated AS-i connection
AS-i Safety at Work
IP67 protection
Controlled key reset
Mushroom-head emergency stop
Safety-related operation
Distributed safety monitoring
Industrial installation
CE approval
cULus approval
ASI approval
UKCA approval
SIL 3 capability
PL e capability
Machine emergency stop
Packaging machinery
Production equipment
Conveyor systems
Machine guarding
Safety networks
AS-i installations
Industrial automation
Operator safety
Emergency shutdown systems
| Specification | Details |
|---|---|
| Product code | AC011S |
| Product type | Key-release E-STOP |
| Connection | Integrated AS-i |
| Safety system | AS-i Safety at Work |
| Protection | IP67 |
| Release method | Key |
| Emergency stop | Yes |
| Operating element | Mushroom-head E-STOP |
| Application | Machine safety |
| Network | AS-i |
| Safety function | Emergency stop |
| Reset function | Key release |
| Installation | Industrial machinery |
| CE | Yes |
| cULus | Yes |
| ASI | Yes |
| UKCA | Yes |
| SIL capability | SIL 3 |
| PL capability | PL e |
| Operator access | Yes |
| Safety monitoring | AS-i |
| Distributed safety | Supported |
| Product category | Safety operating element |
| Primary benefit | Controlled reset |
| Typical environment | Industrial |